background image

1

Performance and Specifications

Item 

Model 

Capacity at regeneration salt levels

Service Flow  

Maximum 

Mineral Tank

Brine Tank

Resin

Salt 

Shipping 

Number

Number

(kilograins as CaCO

3

)

Rate

Flow To Drain

Size

Size

Volume

Capacity

Weight

@15lb/cf

@10lb/cf*

@6lb/cf

USGPM (LPM)

USGPM (LPM)

inches (mm) 

inches (mm) 

cu.ft. (litres)

Lbs. (kg)

Lbs. (kg)

Twin Tank Models

7610

7000MI-30

30

27

20

10.0 (37.9)

2.0 (7.6)

9 x 48 (229 x 1219)

18 x 35 (457 x 889)

1.00 (28.3)

224 (101.6)

85 (38.6)

7611

7000MI-45

45

41

30

12.0 (45.4)

2.4 (9.1)

10 x 54 (254 x 1372)

21 x 36 (533 x 914)

1.50 (42.5)

308 (139.7)

125 (86.7)

7612

7000MI-60

60

55

40

13.0 (49.2)

3.5 (13.2)

12 x 52 (305 x 1321)

21 x 36 (533 x 914)

2.00 (56.6)

308 (139.7)

150 (68)

7613

7000MI-90

90

82

60

15.0 (56.8)

5.0 (18.9)

14 x 65 (356 x 1651)

21 x 36 (533 x 914)

3.0 (84.5)

308 (139.7)

235 (106.6)

7614

7000MI-120

120

108

80

20.0 (75.7)

7.0 (26.5)

16 x 65 (406 x 1651)

21 x 36 (533 x 914)

4.0 (113.3)

308 (139.7)

330 (149.7)

Caution:  These  water  conditioners  are  not  intended  to  be  used  for  treating  water  that  is  microbiologically  unsafe  or  of  unknown  quality  without  adequate
disinfection before or after the system.

Notes: 
Operating Temperature Range:

110°F (43°C)

Operating Pressure Range: 

100 psig (689 kPa)

Electrical: 

24V/60Hz (all units supplied with a 120VAC/60Hz Wall Transformer)

Pipe size:

1”

1. “*” designates that 10 lb/cf is the factory salt setting for all units.
2. Capacities of softeners may deviate from the chart above depending on flow rates and raw water

conditions.

3. The manufacturer reserves the right to make product improvements which may deviate from the

specifications and descriptions stated herein without obligation to change previously manufactured
products or to note the change.

4. 1 Kilograin is equal to 1000 grains.

How Your 7000SXT-DF Water Conditioner Works

Hard water enters your home through the main supply line, enters the softener and passes down through a resin mineral
bed which softens the water. An ion exchange process takes place in which the resin beads capture and hold calcium and
magnesium, the hardness minerals, while the water takes on sodium ions. The soft water then flows into your household
water line.

In normal operation, the Time of Day display will alternate being viewed with the Volume Remaining display. This display
will be in gallons, liters or cubic meters. As treated water is used, the Volume Remaining display will count down from a
maximum value to zero or (---). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time. Water
flow through the valve is indicated by the Flow Indicator that will flash in direct relationship to flow rate. 

Example

833 Gallons of Treated
Water Remaining

0 Gallons of Treated
Water Remaining

Control Operation During Regeneration

In regeneration, the control will display a special regeneration display. In this display, the control will show the current
regeneration step number the valve is advancing to or has reached and the time remaining in that step. The step
number displayed will flash until the valve has completed driving into this regeneration step position. Once all
regeneration steps have been completed, the valve will return to Service and resume normal operation.

Example

Less than 6 minutes
remaining in Regen
Step Rapid Rinse

Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step
position and resume normal step timing.

5

PM Indicator

PM Indicator

Flow Indicator
(Flashing with water flow)

Flow Indicator
(Flashing with water flow)

Содержание 5600SXT Valve

Страница 1: ...7000 SXT Valve Water Softener Operation Manual 54735 Rev 2 09 Read all instructions carefully before operation...

Страница 2: ...s or to note the change 4 1 Kilograin is equal to 1000 grains How Your 7000SXT DF Water Conditioner Works Hard water enters your home through the main supply line enters the softener and passes down t...

Страница 3: ...he system on a timed interval The control will initiate a regeneration cycle at the programmed regeneration time when the number of days since the last regeneration equals the regeneration day overrid...

Страница 4: ...er tube DO NOT use petroleum based lubricants as they will cause swelling of O ring seals The softener or filter is now charged with softening resin It is recommended that the softener or filter tank...

Страница 5: ...be added to the tank to speed up the filling but the valve should be in the Brine Refill position for a minimum of two minutes to purge the air out of the injector set 10 Press the extra cycle button...

Страница 6: ...iated at any time Set Time of Day 1 Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the parameter display reads TD 2 Adjust the displayed time wit...

Страница 7: ...n buttons for five seconds while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corn...

Страница 8: ...t regeneration All individual settings d1 d2 d3 d4 d5 d6 d7 are set to 0 Control board memory failure Unplug the unit from the power source When power is restored to the unit the Err _ display code cl...

Страница 9: ...l regenerations should be performed when little or no water will be used in the household Safety Float The brine tank is equipped with a safety float which prevents your brine tank from over filling a...

Страница 10: ...olution then manually regenerate the softener Care of Your Softener To retain the attractive appearance of your new water softener clean occasionally with a mild soap solution Do not use abrasive clea...

Страница 11: ...r eliminator control Check for dry well condition Drain line flow control is too large Ensure drain line flow control is sized 6 IRON IN CONDITIONED WATER Fouled resin bed Check backwash brine draw an...

Страница 12: ...RAL AND BRINE TANKS HYDROTECH will provide a replacement mineral or brine tank to any original equipment purchaser in possession of a tank that fails within 120 months provided that the water conditio...

Отзывы: