Dip Switch Chart for CS620*B
A1 Test Mode (normally OFF)
A2 “ON” position: Standard mode only
“OFF” position: Std/Ecn/Sleep mode changes allowed
A3 “ON” position: use Mini Panel *
“OFF” position: use Digital Duplex or Light Duplex panel
A4 Aux Freeze (must be OFF)
A5+A9 Pump 1 speeds and Circ Modes:
A6 “ON” position: 50Hz operation
“OFF” position: 60Hz operation
A7 N/A (must remain OFF)
A8 “ON” position: temperature is displayed in degrees Celsius
“OFF” position: temperature is displayed in degrees Fahrenheit
A10 “ON” position: heater is disabled while any high-speed pump or blower is running
“OFF” position: heater can run while any/all high-speed pumps or blowers are running
Note: Aux is required. For no Aux, use CS6100 series system.
Panel Button Positions
Panel Button Assignments
1
1
2
3
4
2 3 4
1=Pump 2 or Blower 3=Temp
2=Pump 1
4=Light
A1, Test Mode OFF
A7, N/A
A2, Mode changes allowed
A10, High Amp mode
A5, 2-speed P1
A9, Non-Circ Mode
IMPORTANT:
Power off spa when making any dip switch changes.
A3: OFF
A3:ON
Circuit Board Configurations
Hot tubs equipped with pump 1 as a single speed pump must utilize a circulation
pump as the heater pump.
A5
A9
Circ Mode
Pump 1 Speed
OFF
OFF
Non-circ
2-speed
ON
OFF
1-speed
Thermostatically Controlled
OFF
ON
24 hours with 3°F shut-off
1-speed
ON
ON
24 hours with 3°F shut-off
2-speed
(low amperage mode)
(high amperage mode)
16
( * = 0,7,8,9 )