38
Press:
Blower bu on on main control to ac vate system.
1) ON/OFF :
1
st
Press: The Blower starts at maximum Speed. LED: ON
2
nd
Press: The blower stops. LED: OFF
2) TO CONTROL SPEED:
Press and hold: Speed goes up or down, LED: ON when pressing.
Release pressure at the desired speed.
3) TO CONTROL PULSATION:
1
st
Press:
Slow Pulsa on Cycle, LED: ON.
2
nd
Press:
Quick Pulsa on Cycle, LED: Flashes.
3
rd
Press:
Pulsa on Cycle OFF, LED: OFF.
1
2
3
TOPSIDE PANEL DISPLAY MESSAGES
Hr
-
An internal hardware error has been detected
Prr
-
The Prr error message indicates a problem with the regula on probe. The system is constantly verifying if the
temperature probe reading is within its normal limits.
HL
-
The water temperature at the heater has reached 119
o
F (48
o
C). Do not enter spa water.
FLO
-
The system did not detect any water flow while the filtra on pump was running.
UPL
-
No low level configura on so ware has been downloaded into the system.
AOH
- The temperature inside the spa skirt is too high, causing the internal temperature in the spa pack to increase above
the normal limits.
OH
-
The water temperature in the spa has reached 108
o
F (42
o
C). Do not enter spa water.
OPTIONAL VARIABLE AIR THERAPY SYSTEM CONTROL FUNCTIONS:
Содержание HSC395G
Страница 50: ...50 IN YE 3 EU WIRING DIAGRAM ...
Страница 51: ...51 IN YE 3 NA WIRING DIAGRAM ...
Страница 52: ...52 IN YE 5 EU WIRING DIAGRAM ...
Страница 53: ...53 IN YE 5 NA WIRING DIAGRAM ...
Страница 54: ...54 IN YT 12 EU WIRING DIAGRAM ...
Страница 55: ...55 IN YT 12 NA WIRING DIA ...