background image

18

 

 

HYDROPOOL SERENITY SERIES CONTROL SYSTEMS NORTH AMERICA/ EUROPE GECKO IN.YE3

 

INITIAL START

-

UP

 

 

Before applying voltage to power

-

up your hot tub, 

it is very important that you understand the      

sequence of events that occur when the system is 

ac vated in order that the pump(s) can be primed 

efficiently and damage to the system can be 

avoided.

 

 

PROGRAM MENU

 

 

The program menu is accessible by holding down 

the Light Key for 5 seconds. In the Program Menu 

the following parameters can be set: clock, filter 

or purge cycles, economy mode and temperature 

units. While in the program menu, use the Up and 

Down keys (Up/ Down Key) to adjust the            

parameters and the Light key to jump to the next 

parameter. The changes will be saved a er the 

confirma on of the last parameter only. If there is 

no ac on taken for 10 seconds, the system will 

exit the program menu without saving any   

changes.

 

 

SETTING THE CLOCK TIME

 

 

Enter the program menu by holding down the 

Light Key for 5 seconds. The display will show the 

current clock se ng with the hour flashing. Use 

the arrow keys to adjust the hour. Press the Light 

Key to adjust the minutes. Press the light key to 

jump to the next parameter or to the end of the 

parameters to save the  me.

 

TEMPERATURE CONTROL

 

FUNCTIONALITY AND 

 

ADJUSTMENT

 

A er you exit the programming mode your hot 

tub will automa cally heat to the factory preset 

default temperature of 38°C (100°F). 

 

 

The temperature shown on the screen is the    

current water temperature. Use the UP and 

DOWN bu ons to set the desired temperature.

 

 

The set point icon will appear at the top of the 

screen. A er 3 seconds without any change to the 

set temperature value, the keypad will resume 

the normal display.

 

STANDBY MODE

 

 

Pressing the JET key for 5 seconds will enable the 

Standby Mode. This mode allows you to stop all 

outputs including automa c func ons such as the 

filter cycle, heat request and smart winter mode 

for 30 minutes to perform quick spa maintenance. 

When ac ve, the display will toggle between the 

“OFF” message, the clock and water temperature

.

 

Содержание HS4300

Страница 1: ...ANUAL Hydropool Inc 335 Superior Blvd Mississauga ON Canada L5T 2L6 Tel 905 565 6810 Toll Free 1 800 465 2933 Fax 905 565 6820 Email info hydropoolho ubs com www hydropoolho ubs com Contents subject t...

Страница 2: ...odes Export Model Codes Serenity 45L NOT APPLICABLE HSE45L Serenity 4300 HS4300 HSE4300 Serenity 4500 HS4500 HSE4500 Serenity 5900 HS5900 HSE5900 Serenity 6600 HS6600 HSE6600 Serenity 6800 HS6800 HSE6...

Страница 3: ...Control Panel Display Messages 23 Op onal Variable Air Therapy System Control 23 Op onal Hydroclear Pure Water System 24 UV C Lamp Replacement 25 Hot Tub Water Balance 26 General Overview 26 Ini al Fi...

Страница 4: ...ruc ons in this manual before electrically connec ng your hot tub and adding water The following pages contain valuable informa on and pointers that will save you both me and money as well as help you...

Страница 5: ...F THIS SPA OR HOT TUB 13 CHILDREN SHOULD NOT ENTER A HOT TUB WHERE THE WATER TEMPERATURE EXCEEDS BODY TEMPERATURE 37 C 98 6 F 14 DO NOT ALLOW CHILDREN TO SUBMERGE THEIR HEAD UNDER WATER 15 NEVER OPERA...

Страница 6: ...PREVENT UNAUTHORIZED ACCESS BY CHILDREN TO AVOID ACCIDENTS ENSURE THAT CHILDREN CAN T USE THE SPA UNLESS THEY ARE SUPERVISED AT ALL TIMES 2 RISK OF INJURY THE SUCTION FITTINGS IN THIS SPA ARE SIZED T...

Страница 7: ...er splashing water inside the home For those who choose an outdoor loca on hot tub opera ng temperatures can be adjusted to match the season In colder months many owners will operate their hot tub in...

Страница 8: ...tub from the deck or cabinet b Where the hot tub is not equipped with a factory installed cabinet it is the installer s responsibility to ensure all electrical equipment is completely weather protect...

Страница 9: ...will be adequately protected If the hot tub is shipped without a cabinet your custom cabinet or other structure must be designed to supply protec on for the hot tub support equipment from rain snow sp...

Страница 10: ...old back the earth is recommended This forms a box or bunker in which the hot tub is placed ALWAYS ensure that there is good drainage via a properly designed French drain gravel system and or a sump p...

Страница 11: ...ger trailer to the lower pro le tow truck at bed The hot tub can be gently slid o the low pro le trailer and posi oned on its side on a cart or dolly on its back side only Most Hydropool models requir...

Страница 12: ...f the supply terminal box or compartment To reduce the risk of electric shock connect the local common bonding grid in the area of the hot tub to these terminals with an insulated or bare copper condu...

Страница 13: ...rom country to country in the CE controlled area Please consult your local installer for advice on breaker level and wire speci ca ons Some examples are below Breaker of 13A wire must be 1 5 mm2 Break...

Страница 14: ...lectrician in accordance with the Na onal Electrical Code or the Canadian Electrical Code and all Federal State Provincial and local codes and regula ons in e ect at the me of installa on Hydropool hi...

Страница 15: ...izing and selec on of conductor size and type must be performed by a quali ed electrician in accordance with Na onal Regional and Local Codes and Regula ons in e ect at the me of installa on NOTICE 23...

Страница 16: ...easy access and inexpensive correc on Check all union connec ons and plumbing for minor leaks In the event of a leak ensure all union connec ons and pump plugs are ght and all o rings gaskets are in...

Страница 17: ...rrantable damage to the pump it may also cause the control system to go into an overheat condi on Turn the hydrotherapy pump s onto high speed and re check for leaks The control system will automa cal...

Страница 18: ...menu by holding down the Light Key for 5 seconds The display will show the current clock se ng with the hour ashing Use the arrow keys to adjust the hour Press the Light Key to adjust the minutes Pres...

Страница 19: ...CONTROL SYSTEMS NORTH AMERICA EUROPE 4300 4500 6600 SE45L MODELS KEYPAD FUNCTIONS AND DISPLAY ICONS JET KEY WHICH CONTROLS PUMP 1 ILLUM KEY WHICH CONTROLS THE LIGHTING AND THE PROGRAMMING TEMPERATURE...

Страница 20: ...TROL SYSTEMS NORTH AMERICA EUROPE 5900 6800 6900 MODELS KEYPAD FUNCTIONS AND DISPLAY ICONS JET KEY WHICH CONTROLS PUMP 1 ILLUM KEY WHICH CONTROLS THE LIGHTING AND THE PROGRAMMING TEMPERATURE UP DOWN K...

Страница 21: ...resen ng the dura on in hours of the lter cycle Use the arrow keys to adjust the dura on Use the Light Key to jump to the next parameter lter frequency FF The display will show FFxx with xx represen n...

Страница 22: ...e ltra on pump remains on for a certain amount of me to ensure adequate cooling of the hea ng element in order to prolong the useful life of the heater The heater icon ashes during this me HYDROPOOL S...

Страница 23: ...p or down LED ON when pressing Release pressure at the desired speed 3 TO CONTROL PULSATION 1st Press Slow Pulsa on Cycle LED ON 2nd Press Quick Pulsa on Cycle LED Flashes 3rd Press Pulsa on Cycle OFF...

Страница 24: ...tory eye and skin irrita on typically associated with chlorine Harmful corrosive o gassing is also drama cally reduced through this process MAINTENANCE AND SERVICE While opera ng check regularly to se...

Страница 25: ...ke sure to use latex glove when handling the UV C lamp 6 3 Slowly disconnect the old UV C lamp connector 5 from the ballast connector 4 4 Slowly remove the old UV C lamp 6 from the UV unit 5 Slide the...

Страница 26: ...s will literally drop or precipitate out of the water and deposit on the hot tub walls plumbing jets in the lter and on the heater element It is very important that pH be checked frequently and mainta...

Страница 27: ...r Chlorine to the dispenser Built in dispenser if your Hydropool hot tub was ordered with the op onal built in bromine chlorine dispenser located under the basket of the cartridge lter housing refer t...

Страница 28: ...o 7 6 ppm 8 pH INCREASER raises the pH level of the water 9 pH DECREASER lowers the pH level of the water 10 TOTAL ALKALINITY TA the amount of carbonate bicarbonate and hydroxide compounds present in...

Страница 29: ...linity High pH levels High Calcium Hardness Test these water balance elements and adjust to recommended parameters Scale White Grayish Deposit High Calcium Hardness Test calcium hardness level and tre...

Страница 30: ...sive Low Calcium Hardness Test calcium hardness and if necessary increase with calcium chloride Corrosion Etching Presence of metals in water iron copper etc Test total alkalinity levels and if necess...

Страница 31: ...tainless steel components that are above the waterline MONTHLY Soak your filter cartridge in a filter cartridge cleaning solution Rinse thoroughly and if possible allow to dry before re installing Hyd...

Страница 32: ...be purchased from your HYDROPOOL Hot tub Retailer 8 Rinse thoroughly and dry before replacing 9 Hydropool recommends purchasing a spare lter cartridge so that you always have a clean subs tute ready t...

Страница 33: ...to be sure that the drain shut o valve is closed turn handle clockwise un l it stops 2 Check that the safety cap is securely in place 3 If the drain valve is facing a wall leave enough space between t...

Страница 34: ...es on the leaf bag slip onto each hook on the clips In order to clean the leaf bag of any dirt or debris you need to unclip it from the back of the grill and clean it accordingly removing all of the d...

Страница 35: ...earance They are hinged in the middle for easier handling and the zip fastener allows the tapered foam inserts to be changed if damaged The skirt of the safety hard cover overlaps the lip of the hot t...

Страница 36: ...a standard feature on the 4300 4500 5900 6600 6800 6900 and SE45L Serenity models to provide a be er grip trac on and comfort on both the steps and oor of the spa Making your spa safe and easy to use...

Страница 37: ...r channels 9 Reinstall all jet inserts and all suction covers DO NOT USE AUTOMOTIVE ANTIFREEZE Important mixing potable biodegradable RV antifreeze with water significantly reduces its ability to prot...

Страница 38: ...hows par al messages try rese ng the system by turning power to the hot tub o wai ng a few minutes then turning power on again If this does not reset the system contact your local Hydropool retailer o...

Страница 39: ...39 IN YE 3 EU WIRING DIAGRAM...

Страница 40: ...40 IN YE 3 NA WIRING DIAGRAM...

Отзывы: