IV. INSTALLATION AND CONNECTION

1. Installation

·  Pump should be sited in a well ventilated but frost-free position. The
  distance between pump with motor and other objects should be at least 150mm,
  in order to cool the motor by fan with enough air.
· To reduce the head loss of inlet as least as possible, the inlet pipe shall
  be as short as possible.
· Ensure the check valve is installed in pipe line system before the pump
  installation to prevent liquid from returning.
· Pump should be fixed in ground or fixed on the brackets on wall. Pump
  should be safely flxed and stable. Pay attention not to let the weight of pipe
  system on pump to prevent pump from damage.
· Before pump installation. the inlet pipeline shall be cleaned. If there
  is impurities in the pipe, it is necessary to install a strainer at 0.5-1mm in front
  of the pump inlet.
· The air pockets shall be avoided when installing the inlet pipe line. 

See Fig. 2

Air

Air

Air

Wrong

Correct

· It is necessary to flt a pressure meter to observe and control operation
of pump.
· When the height of pump position is higher than liquid level, in the suction
range of pump, a foot valve should be installed in the inlet pipe end.
And fit a water pouring screw hole in the drainage pipe. It is used for pouring
water in before starting pump.

2. Electrical connection

· The electrical connections should be carried out by a qualified electrician.
· To make sure the motor is suitable for the power supply, cables ofthe
motor must be connected to power supply according to the Fig. on the terminal
box and the motor nameplate.
· Motor shall be connected with a fast and effective motor starter, to ensure
that the motor will not be damaged by lack of phase, unstable voltage
or overload. The motor shall be earthed reliably.

Caution: Before take apart the terminal box cover or dismantle pump, make
sure that the power supply is switched off.

Warning - Electrical connection and safety devices

·  The pump units should be connected to the power supply by the appropriately
  rated power cables according to the motor ratings.
·  The pump units should always be equipped with safety devices as required
  in the standards (EN 809 and/or EN 60204-1) as well as by the national
  rules of the country where the pump is used.
·  Despite the rules of any country, the power supply to the pump unit
  must be equipped with at least following electrical safety devices with appropriate
 ratings:
  - Emergency switch
  - Circuit breaker (as a supply disconnecting (isolating) device as well as an overcurrent
    protective device)
  - Motor overload protection

The following table is for suggestion:
3 phase motors:

Single phase motors:

The acoustic noise emission is around 75 dB (A).

Before open the terminal box, please shut off the power  
supply to prevent from power shock.

380V (50Hz/60Hz)

No. Power input (Kw)

Cable 

connection

Input 

current (A)

Cable spec 

(mm

2

)

Circuit breaker 

(A)

Thermal 

protector (A)

1

0.37

Y

1

0.75

5

1.2

2

0.55

Y

1.4

0.75

5

1.7

3

0.75

Y

1.8

0.75

5

2.2

4

1.1

Y

2.6

1

5

3.1

6

1.5

Y

3.5

1

10

4.2

8

2.2

Y

4.9

1.5

10

5.9

11

3

6.3

1.5

10

7.6

13

4

8.2

2.5

20

9.8

15

5.5

11

2.5

20

13.2

IE1 MOTOR 230 V 50 Hz

Type

Current (A)

Power (kW)

Speed (rpm)

Efficiency (%)

YY-711-2

2,37

0,37

0.75

YY-712-2

3,88

0,55

0.75

YL-801-2

5,15

0,75

0.75

YL-802-2

7,02

1,1

2900

1

YL-90S-2

9,44

1,5

1

YL-90L-2

13,67

2,2

1.5

Содержание HDROO Series

Страница 1: ...HYDROO Pump Industries SL HF HX HN Light Horizontal Multistage Centrifugal Pump Operation Manual HDROO SERIES ...

Страница 2: ...25 EC Machinery directive 2006 42 EC Commission Regulation 547 2012 Standard EN809 1998 A1 2009 Commission Regulation 640 2009 Place of Issue Palol de Revardit Spain Name of authorlsed representative Miquel Coma Position of authorlsed representative CEO Declaration I declare that as the authorised representative the above information in relation to the supply manufacture of this product is in conf...

Страница 3: ...Liquid transferring circulation boosting Hot or cold water Feed proportioning system of food drinking agriculture etc 2 Operation conditions Liquid temperature Normal temperature type 15ºC 70ºC Hot water type 15ºC 110ºC Flow range 0 5 28 m3 h Max pressure 10 bar Liquid pH range pH5 9 Max ambient temperature 40ºC The Max suction pressure is limited by max operating pressure Min inlet pressure Refer...

Страница 4: ...4 Impeller 7 Discharge 8 Mechanical Seal 10 Base plate 11 Staybolt 12 Diffuser 12a Neck ring retainer 12b Neck ring 13 Support diffuser W O this part in 2 3 stages pump 14 Impeller sleeve 15 Sleeve 1 W O this part in HF HX HN 2 17 Seal ring 18 Impeller sleeve S W O this part in 2 3 stages pump 19 First impeller cover 20 Nut 23 O ring 24 Spring washer 25 Nut 28 Screw 29 Spring Washer 31 Washer 32 M...

Страница 5: ...he motor nameplate Motor shall be connected with a fast and effective motor starter to ensure that the motor will not be damaged by lack of phase unstable voltage or overload The motor shall be earthed reliably Caution Before take apart the terminal box cover or dismantle pump make sure that the power supply is switched off Warning Electrical connection and safety devices The pump units should be ...

Страница 6: ... fully Fill water in pump in inverse pouring system Close the pump outlet valve release air vent screw on the pump head and open the inlet valve slowly until stable water flows from the air vent screw Then fasten the screw Fill water in pump when liquid level is lower than pump Before installing pump and pipes must be filled with liquid fully and air vented 2 Check the rotary direction Switch on t...

Страница 7: ... is not choked Reverse the process above can disassemble a pump VII Fault finding and solution chart Caution Before removing the terminal box cover and before any removal dismantling of the pump make sure that the power supply has been switched off Fault Cause Solution Remarks Motor does not run when started a Power supply failure a Check power supply b Fuses are blown b Replace fuses c Motor is o...

Страница 8: ...ck valve is defective b Check and repair foot valve or check valve c Foot valve is blocked in opened or partly opened position c Check and repair foot valve d There is air in suction pipe d Check and repair suction pipe and release air Fault Cause Solution Remarks Abnormal vibration or noise from pump a Leakage in suction pipe a Check and repair suction pipe In the case of e users shall not disass...

Страница 9: ...rtners 201902 IOM HFHXHN EN subject to amendments HYDROO Pump Industries SL C La Banyeta Nova 11 P I La Banyeta 17843 Palol de Revardit Girona Catalonia Spain Tel 34 972 394 654 E mail info hydroo com www hydroo com ...

Отзывы: