Read this manual carefully  

before install, start the pump.

I. AppLICATIONS AND CONDITIONS 

HF, HX, HN are non-self-priming light horizontal multistage
centrifugal pump (abbr. as pump in the following). They are efficient, low noise,
little corrosive tolerance, compact structure, good looking, small volume,
light weight, etc.

1. Applications 

·   Pumped liquids: Low viscosity, neutral, non-explosive liquids, not
  containing so lid particles or fibres. The liquid must not attack the pump
  materials chemically. (Oil or the liquid mainly consisted of oil can be pumped
  by special type of pumps);
·   Circulation for air condition system;
·   Cooling system;
·   Water treatment, purification system;
·   Industry cleaning system;
·   Liquid transferring, circulation, boosting;
·   Hot or cold water;
·   Feed proportioning system of food, drinking, agriculture, etc.

2. Operation conditions

·   Liquid temperature: Normal temperature type -15ºC~+70ºC ;
  Hot water type -15ºC ~+ 110ºC;
·   Flow range: 0.5~28 m

3

/h

·   Max pressure: 10 bar
·   Liquid pH range: pH5 ~9
·   Max ambient temperature: +40ºC
·   The Max suction pressure is limited by max operating pressure;
·   Min inlet pressure: Refer to HDROO catalogue.
 
 

Caution: When pumping liquids with a density and/or viscosity higher

  than that of water, use motors with correspondingly higher outputs, if 

required.

II. DEFINITION OF MODEL 

H

F

4

40

S

5

2

0’75

0023

Number of poles

5: 50 Hz

6: 60 Hz

Rated voltage (x10) (V)

S: one phase

T: three phases

Power P2 (kW) 

Normal temperature omitted

R:High temperature

Number of stages(x10)

Rated flow (m3/h)

F: cast iron version

X: SS304wet parts

N: SS316 wet parts

Horizontal Multistage 

Centrifugal Pump

-

Содержание HDROO Series

Страница 1: ...HYDROO Pump Industries SL HF HX HN Light Horizontal Multistage Centrifugal Pump Operation Manual HDROO SERIES ...

Страница 2: ...25 EC Machinery directive 2006 42 EC Commission Regulation 547 2012 Standard EN809 1998 A1 2009 Commission Regulation 640 2009 Place of Issue Palol de Revardit Spain Name of authorlsed representative Miquel Coma Position of authorlsed representative CEO Declaration I declare that as the authorised representative the above information in relation to the supply manufacture of this product is in conf...

Страница 3: ...Liquid transferring circulation boosting Hot or cold water Feed proportioning system of food drinking agriculture etc 2 Operation conditions Liquid temperature Normal temperature type 15ºC 70ºC Hot water type 15ºC 110ºC Flow range 0 5 28 m3 h Max pressure 10 bar Liquid pH range pH5 9 Max ambient temperature 40ºC The Max suction pressure is limited by max operating pressure Min inlet pressure Refer...

Страница 4: ...4 Impeller 7 Discharge 8 Mechanical Seal 10 Base plate 11 Staybolt 12 Diffuser 12a Neck ring retainer 12b Neck ring 13 Support diffuser W O this part in 2 3 stages pump 14 Impeller sleeve 15 Sleeve 1 W O this part in HF HX HN 2 17 Seal ring 18 Impeller sleeve S W O this part in 2 3 stages pump 19 First impeller cover 20 Nut 23 O ring 24 Spring washer 25 Nut 28 Screw 29 Spring Washer 31 Washer 32 M...

Страница 5: ...he motor nameplate Motor shall be connected with a fast and effective motor starter to ensure that the motor will not be damaged by lack of phase unstable voltage or overload The motor shall be earthed reliably Caution Before take apart the terminal box cover or dismantle pump make sure that the power supply is switched off Warning Electrical connection and safety devices The pump units should be ...

Страница 6: ... fully Fill water in pump in inverse pouring system Close the pump outlet valve release air vent screw on the pump head and open the inlet valve slowly until stable water flows from the air vent screw Then fasten the screw Fill water in pump when liquid level is lower than pump Before installing pump and pipes must be filled with liquid fully and air vented 2 Check the rotary direction Switch on t...

Страница 7: ... is not choked Reverse the process above can disassemble a pump VII Fault finding and solution chart Caution Before removing the terminal box cover and before any removal dismantling of the pump make sure that the power supply has been switched off Fault Cause Solution Remarks Motor does not run when started a Power supply failure a Check power supply b Fuses are blown b Replace fuses c Motor is o...

Страница 8: ...ck valve is defective b Check and repair foot valve or check valve c Foot valve is blocked in opened or partly opened position c Check and repair foot valve d There is air in suction pipe d Check and repair suction pipe and release air Fault Cause Solution Remarks Abnormal vibration or noise from pump a Leakage in suction pipe a Check and repair suction pipe In the case of e users shall not disass...

Страница 9: ...rtners 201902 IOM HFHXHN EN subject to amendments HYDROO Pump Industries SL C La Banyeta Nova 11 P I La Banyeta 17843 Palol de Revardit Girona Catalonia Spain Tel 34 972 394 654 E mail info hydroo com www hydroo com ...

Отзывы: