6.  Check  pump  for  proper 

rotation  before  re turn ing  to 
normal service.

replacing Stator:

If  motor  winding  is  burned  or
shorted,  it  can  be  rewound  or
replaced with new factory wound
sta tor.  Refer  to  sectional  drawing
of  pump  and  motor,  and  use  the
following  steps  to  remove  and
replace stator.
1.  If only the stator is damaged, it

may  not  be  necessary  to 
com plete ly dismantle pump as 
stator and housing can be lifted
from  pump  without  dis turb ing
seals or bearings.

2.  Drain all oil from upper housing.

Remove  drain  plug  in  bottom 
of  bearing  housing,  and 
re move  con nec tion  box  to
allow air to enter.

3.  When  connection  box  is 

lifted  off,  con nec tion  wires  to 
motor  will  be  exposed.  These
wires  are  tagged  with  a  metal 
marker  giving  wire  num ber.
Disconnect  wires  and  remove
connection box.

4.  After  chamber  is  drained,

remove  hold-down  bolts  on
motor housing and lift off. Use
care in lifting as the seal failure
connecting  wire  must  be 
disconnected  before  hous ing 
is  completely  re moved.  See 
sectional drawing.

5.  The stator is held in the housing

with  a  bolted-in  retaining  ring
and pre vent ed from rotating by
a roll pin.

6.  Remove the retaining ring and

socket head cap screw.

Pump
Maintenance

7.  After  ring  is  removed,  turn 

hous ing  upright  and  bump  on
hard wood  block.  This  should
jar the stator loose and allow it
to drop out.

8.  Thoroughly  clean  housing

before  replacing  new  stator.
Replace  sta tor  and  make  all
wire con nec tions to con nec tion
box  before  re plac ing  housing
on  pump.  See  motor  lead 
connection  drawing.  This  is
important  as  leads  must  be
tucked  behind  the  windings 
by  using  hands  up  through
rotor core.

iMPortANt:  Use  only  butt 
con nec tions on the wires. 
Do  not  tape  leads  as  oil  will 
de te ri o rate  the  tape  and  cause 
dam age to stator and bearings.

9.  Check top bearing. If the bearing

is  clean  and  does  not  turn
rough, bearings can be reused.

If  bear ings  are  damaged  with
dirt  or  heat,  they  must  be
replaced. 

See 

addi tion al

instructions on replacing seals
and bearings.

10.Replace  stator  housing  onto

seal chamber and bolt in place.
Be  sure  seal  failure  wires 
are  con nect ed  before  housing
is as sem bled.

    Be  sure  O-ring  seal  has  been 

re placed. If O-ring is nicked or
cut,  replace  with  new  ring.
This  ap plies  to  all  O-rings
used in as sem bly.

11.After all leads are reconnected

in  the  con nec tion  box  (see
Figure  1,  Page  11),  make  a
high  voltage  ground  test  on
each  wire. The  only  wire  that
should  show  ground  is  the
green  power  lead  and  the
ground  head  in  the  aux il ia ry 
control cable.

12.For  safety,  complete  pump

should  be  air  checked  under
water for leaks.

Содержание S4NX

Страница 1: ... E 03 332 Part 5625 332 1 2010 Pentair Pump Group Inc Installation and Service Manual NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system For use with product built with Regal Beloit Marathon motor ...

Страница 2: ... longer and prior to electrical start up Seal Failure Probes All hazardous location submersible pumps have two factory installed moisture detectors seal failure probes They are in a normally open series circuit in the seal chamber Under normal operating conditions the circuit remains open If the lower seal leaks and moisture enters this chamber the moisture would settle to the bottom of the chambe...

Страница 3: ...s recommended Hydromatic warranty is void See Pages 5 6 Heat Sensor and Seal Failure Connections If a Hydromatic control panel is used terminal blocks are provided for heat sensor and seal failure connections See Panel Schematic If a control panel is supplied by others it must allow heat sensor and seal failure terminations Starting System 1 Double check all wire connections 2 Turn pumps to Off po...

Страница 4: ... on a pump the following instructions should be followed carefully Disconnecting Pump Cords If a Hydromatic hazardous location pump is to be removed from its location one of two ways may be used to disconnect the pump cords from the rest of the system Pump cords may be disconnected at control panel on sump mounted control panels and cord assembly taken with pump CAUtioN if cord openings from sump ...

Страница 5: ...NNECTIONS O L O L L2 FUSES GREEN RED BLACK WHITE PUMP MOTOR F E RED 330K D C GREEN HEAT SENSORS 120 VAC 5A SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW CRS RUN CAPACITOR CRS START CAPACITOR CAPACITOR PACK PANEL M RUN LIGHT SEAL FAILURE INDICATOR D C TO SEAL PROBES IN PUMP MOTOR SEAL FAILURE RELAY LEVEL CONTROL CIRCUITRY H O A H A R OVERLOADS CAPACITORS AND ...

Страница 6: ... PUMP MOTOR RED 330K D C GREEN HEAT SENSORS 120 VAC 5A SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW CRS RUN CAPACITOR CRS START CAPACITOR CAPACITOR PACK PANEL M RUN LIGHT SEAL FAILURE INDICATOR R F E PUSH TO RESET R TO HEAT SENSOR IN PUMP MOTOR D C PUSH TO TEST SEAL PROBE CONTINUITY TEST LIGHT TO SEAL PROBES IN PUMP MOTOR SEAL FAILURE RELAY LEVEL CONTROL CI...

Страница 7: ...p Maintenance 7 After ring is removed turn housing upright and bump on hardwood block This should jar the stator loose and allow it to drop out 8 Thoroughly clean housing before replacing new stator Replace stator and make all wire connections to connection box before replacing housing on pump See motor lead connection drawing This is important as leads must be tucked behind the windings by using ...

Страница 8: ...e shaft by tapping the end of the impeller blades 4 To remove seal plate take out socket head screws and using screws in back off holes pry plate loose This will also force seal off if not already removed 5 Remove snap ring Pull seal if it is free If not free it can be forced off when shaft is removed 6 Set seal housing in upright position and bump end of shaft on hardwood block This will push the...

Страница 9: ...PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY Wiring Diagrams ...

Страница 10: ...ator 3 HP 230 1 60 1750 1 14698 203 1 Stator 3 HP 200 1 60 1750 1 24407C202 Stator 3 HP 230 460 3 60 1750 1 24407C201 Stator 3 HP 200 3 60 1750 1 24407C203 Stator 3 HP 575 3 60 1750 1 24407C204 Stator 5 HP 230 1 60 1750 1 24407C206 Stator 5 HP 230 460 3 60 1750 1 24407C205 Stator 5 HP 200 3 60 1750 1 24407C207 Stator 5 HP 575 3 60 1750 1 Ref Part Part No No Description Qty 24407C209 Stator7 1 2HP2...

Страница 11: ...34 48 25 47 39 45 41 40 46 1 2 3 4 5 6 7 8 9 10 12 11 13 14 16 17 18 19 20 21 22 23 43 44 S4NX CONNECTION DIAGRAM FOR LEADS IN MOTOR AND CONNECTION BOX 230 VOLTS 460 VOLTS GREEN GREEN L3 L2 L1 L3 L2 L1 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 Figure 1 ...

Страница 12: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 13: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 14: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Страница 15: ......

Страница 16: ...oltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well T Yes T No Are Floats Set to Engineer s Specs T Yes T No Are Floats Wired for Proper Seq...

Отзывы: