Hydromatic S4NX Скачать руководство пользователя страница 14

– Your Authorized Local Distributor –

www.hydromatic.com

STANDARD LIMITED WARRANTY

 

    

HYDROMATIC

®

 warrants its products against defects in material and workmanship for a period of 12 months 

from the date of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - 
provided  that  such  products  are  used  compliance  with  the  requirements  of  the  Hydromatic  catalog  and          
technical  manuals  for  use  in  pumping  raw  sewage,  municipal  wastewater  or  similar,  abrasive  free                 
non-corrosive liquids. 

During the warranty period and subject to the conditions set forth, Hydromatic, at its discretion, will repair or 
replace  to  the  original  user,  the  parts  which  prove  defective  in  materials  and  workmanship.  Hydromatic 
reserves the right to change or improve its products or any portions thereof without being obligated to provide 
such a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics

 may be required to support warranty claims. Warranty is 

effective only if Hydromatic authorized control panels are used. All seal fail and heat sensing devices must be 
hooked up, functional and monitored or this warranty will be void. Hydromatic will only cover the lower seal 
and labor thereof for all dual seal pumps. Under no circumstance will Hydromatic be responsible for the cost 
of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from 
the factory or an authorized Hydromatic service facility.

This limited warranty will not apply:

 (a) to defects or malfunctions resulting from failure to properly 

install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting 
from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such 
service; (d) to units which are not installed in accordance with applicable local codes, ordinances and good 
trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other 
than for what it is designed and manufactured; (g) to any unit which has been repaired or altered by anyone 
other than Hydromatic or an authorized Hydromatic service provider; (h) to any unit which has been repaired 
using non factory specified/OEM parts.

Warranty Exclusions:

 HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND 

BEYOND THE DESCRIPTION ON THE FACE HEREOF. HYDROMATIC SPECIFICALLY DISCLAIMS THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation:

  IN  NO  EVENT  SHALL  HYDROMATIC  BE  LIABLE  OR  RESPONSIBLE  FOR                    

CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER 
TO ANY HYDROMATIC PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE 
MAY  RESULT  FROM  IMPROPER  INSTALLATION.  HYDROMATIC  DISCLAIMS  ALL  LIABILITY,  INCLUDING   
LIABILITY  UNDER  THIS  WARRANTY,  FOR  IMPROPER  INSTALLATION.  HYDROMATIC  RECOMMENDS   
INSTALLATION BY PROFESSIONALS.

Some  states  do  not  permit  some  or  all  of  the  above  warranty  limitations  or  the  exclusion  or  limitation  of              
incidental  or  consequential  damages  and  therefore  such  limitations  may  not  apply  to  you.  No  warranties          
or  representations  at  any  time  made  by  any  representatives  of  Hydromatic  shall  vary  or  expand  the                 
provision hereof.

USA

740 East 9th Street, Ashland, Ohio 44805

Tel: 419-289-3042  Fax: 419-281-4087

CANADA

269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5

Tel: 519-896-2163  Fax: 519-896-6337

Warranty Rev 02/09

Содержание S4NX

Страница 1: ... E 03 332 Part 5625 332 1 2010 Pentair Pump Group Inc Installation and Service Manual NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system For use with product built with Regal Beloit Marathon motor ...

Страница 2: ... longer and prior to electrical start up Seal Failure Probes All hazardous location submersible pumps have two factory installed moisture detectors seal failure probes They are in a normally open series circuit in the seal chamber Under normal operating conditions the circuit remains open If the lower seal leaks and moisture enters this chamber the moisture would settle to the bottom of the chambe...

Страница 3: ...s recommended Hydromatic warranty is void See Pages 5 6 Heat Sensor and Seal Failure Connections If a Hydromatic control panel is used terminal blocks are provided for heat sensor and seal failure connections See Panel Schematic If a control panel is supplied by others it must allow heat sensor and seal failure terminations Starting System 1 Double check all wire connections 2 Turn pumps to Off po...

Страница 4: ... on a pump the following instructions should be followed carefully Disconnecting Pump Cords If a Hydromatic hazardous location pump is to be removed from its location one of two ways may be used to disconnect the pump cords from the rest of the system Pump cords may be disconnected at control panel on sump mounted control panels and cord assembly taken with pump CAUtioN if cord openings from sump ...

Страница 5: ...NNECTIONS O L O L L2 FUSES GREEN RED BLACK WHITE PUMP MOTOR F E RED 330K D C GREEN HEAT SENSORS 120 VAC 5A SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW CRS RUN CAPACITOR CRS START CAPACITOR CAPACITOR PACK PANEL M RUN LIGHT SEAL FAILURE INDICATOR D C TO SEAL PROBES IN PUMP MOTOR SEAL FAILURE RELAY LEVEL CONTROL CIRCUITRY H O A H A R OVERLOADS CAPACITORS AND ...

Страница 6: ... PUMP MOTOR RED 330K D C GREEN HEAT SENSORS 120 VAC 5A SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW CRS RUN CAPACITOR CRS START CAPACITOR CAPACITOR PACK PANEL M RUN LIGHT SEAL FAILURE INDICATOR R F E PUSH TO RESET R TO HEAT SENSOR IN PUMP MOTOR D C PUSH TO TEST SEAL PROBE CONTINUITY TEST LIGHT TO SEAL PROBES IN PUMP MOTOR SEAL FAILURE RELAY LEVEL CONTROL CI...

Страница 7: ...p Maintenance 7 After ring is removed turn housing upright and bump on hardwood block This should jar the stator loose and allow it to drop out 8 Thoroughly clean housing before replacing new stator Replace stator and make all wire connections to connection box before replacing housing on pump See motor lead connection drawing This is important as leads must be tucked behind the windings by using ...

Страница 8: ...e shaft by tapping the end of the impeller blades 4 To remove seal plate take out socket head screws and using screws in back off holes pry plate loose This will also force seal off if not already removed 5 Remove snap ring Pull seal if it is free If not free it can be forced off when shaft is removed 6 Set seal housing in upright position and bump end of shaft on hardwood block This will push the...

Страница 9: ...PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY Wiring Diagrams ...

Страница 10: ...ator 3 HP 230 1 60 1750 1 14698 203 1 Stator 3 HP 200 1 60 1750 1 24407C202 Stator 3 HP 230 460 3 60 1750 1 24407C201 Stator 3 HP 200 3 60 1750 1 24407C203 Stator 3 HP 575 3 60 1750 1 24407C204 Stator 5 HP 230 1 60 1750 1 24407C206 Stator 5 HP 230 460 3 60 1750 1 24407C205 Stator 5 HP 200 3 60 1750 1 24407C207 Stator 5 HP 575 3 60 1750 1 Ref Part Part No No Description Qty 24407C209 Stator7 1 2HP2...

Страница 11: ...34 48 25 47 39 45 41 40 46 1 2 3 4 5 6 7 8 9 10 12 11 13 14 16 17 18 19 20 21 22 23 43 44 S4NX CONNECTION DIAGRAM FOR LEADS IN MOTOR AND CONNECTION BOX 230 VOLTS 460 VOLTS GREEN GREEN L3 L2 L1 L3 L2 L1 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 Figure 1 ...

Страница 12: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 13: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 14: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Страница 15: ......

Страница 16: ...oltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well T Yes T No Are Floats Set to Engineer s Specs T Yes T No Are Floats Wired for Proper Seq...

Отзывы: