Touch “STATUS” (1) to check current working status.
Touch “PARAMETER” (2) to set working parameter.
Touch “SYSTEM” (3) to set system setting.
Touch “VERSION” (4) to check version information.
MAIN MENU INTERFACE
• Touch (1) to switch ballast rated power (available options are 400W, 600W, 750W and
1000W).
• Touch (2) to set output mode: M-On (Manual on), M-Off (Manual off), or Auto.
• Touch (3) to set power output percentage (valid values here are 50-110). Under “Auto” mode,
if the sunrise/sunset function is disabled, it will execute this output immediately once lights
are powered on. If the sunrise/sunset function is enabled, this value is the final output after
sunrise/sunset simulation. Zone B settings are made the same way.
• Touch (4) to set Time On (the time when the LT1 turns on the lights in this zone) (24 hr time
format). Zone B settings are made the same way.
• Touch (5) to set Time Off (the time when the LT1 turns off the lights in this zone) (24 hr time
format). Zone B settings are made the same way.
• Touch “SAVE” (6) to save current settings.
• Touch “NEXT” (7) to go to the next page.
• Touch “CANCEL” (8) to return to the
previous page.
• Touch “DEFAULT” (9) to restore factory default
settings. It will display a confirmation prompt to
avoid unintentional operation.
PARAMETER INTERFACE
Sensor T2 disconnect
2017-11-21 17.25
PARAMETER
DEFAULT
Ballast
Output
Time On
Time Off
ZONE A
SAVE
NEXT
CANCEL X
ZONE B
1000W
Auto
100
Auto
60
1000W
30
06
30
06
30
17
30
17
1
2
3
4
5
6
7
8
9
1
2
3
4
refers to the auto-shutdown temperature. If the room temperature exceeds this value, the LT1
will shut the dimming output and close the WRN dry connect, also disconnect EMI1 and close
EMI2.
• Touch “SET MODE” (11) to choose the output mode. The output setting here is only temporarily
effective (it is not stored when the unit is powered down). It will revert to the output mode
which is set in the parameter interface after restart.
• This display (12) shows the output status of extension modules and warning connections
(normally open). OFF = open, ON= closed.
A. During lights on period, EMI1 dry contact is not energized and EMI2 dry contact is energized;
B. During lights off period, EMI dry contact is energized and EMI2 dry contact is not energized;
3) When temperature is over limit value T-Limit 2, WRN dry contact will be energized, EMI1 dry
contact remains energized and EMI2 dry contact will not be energized. If there is no sensor
connected to the appointed zone, all dry contacts will not be energized and the LT1 will forbid
all output and auto-actions (including lights on, lights off, auto-dimming when temperature is
over T-Limit 2, and auto-shutdown when temperature is over T-Limit 2).
• Warning information displays in this area (13). Multiple items of warning information will be
displayed alternately.