XTC1100

USER MANUAL

LT1 DIGITAL LIGHTING CONTROLLER

Содержание Xtrasun LT1

Страница 1: ...XTC1100 USER MANUAL LT1 DIGITAL LIGHTING CONTROLLER ...

Страница 2: ...Hydrofarm com 2 ...

Страница 3: ... IN THE BOX 5 DIMENSIONS 6 PORT CONNECTIONS 6 INSTALLATION 7 CONNECTING THE CONTROLLER TO COMPLETE LIGHTING FIXTURES 7 CONNECTING THE CONTROLLER TO REMOTE BALLASTS 7 OPERATING INSTRUCTIONS 8 MAIN MENU INTERFACE 9 PARAMETER INTERFACE 9 PARAMETER INTERFACE 2 10 SYSTEM INTERFACE 10 WARRANTY 12 3 ...

Страница 4: ...vent of overtemperature sunrise sunset simulation and two connections for external equipment such as dehumidifiers and air conditioning systems For additional information on Xtrasun and Hydrofarm products please visit Hydrofarm com TOOLS NEEDED FOR ASSEMBLY TOOL Type SPECIFICATIONS Voltage input DC 5V 2A 0 11V output ports 2 Temperature sensor ports 2 Relay output ports 3 Optional ballast type 400...

Страница 5: ...PARTS LIST WHAT S IN THE BOX A Controller B Power adapter C Temperature humidity sensor 2 Length 20 6 m D Dry contact adapter E RJXX cables 2 Length 10 3 m F Screw pack not shown 6 pcs A B C D E 5 ...

Страница 6: ...2 0 11V Zone B output port RJ9 3 0 11V Zone A output port RJ9 4 Alarm light normally open 5 External extension port of Zone B output normally open 6 External extension port of Zone A output normally open 7 Zone B temperature sensor input 8 Zone A temperature sensor input 1 2 3 4 5 6 7 8 6 ...

Страница 7: ...ter to the input of the following splitter 6 Repeat this process to connect up to 80 ballasts per zone CONNECTING THE CONTROLLER TO REMOTE BALLASTS 1 Switch the rotary knob on all ballasts to EXT 2 Insert the RJ9 end of the provided cable into the Zone A P1 or Zone B P2 port of the LT1 controller 3 Insert the RJ14 end of the provided cable into one of the two RJ14 ports of the first ballast 4 Use ...

Страница 8: ... setting output 2 During Sunset period the icon will keep flashing until the output reaches 50 and the output will be closed automatically 3 When the Temp Auto dim warning displays the icon will keep flashing and it will reduce the output as setting percentage After the output comes to 50 and no longer dims down the icon will still flash until the temperature drops to at least 2 C lower than the n...

Страница 9: ... 17 25 PARAMETER DEFAULT Ballast Output Time On Time Off ZONE A SAVE NEXT CANCEL X ZONE B 1000W Auto 100 Auto 60 1000W 30 06 30 06 30 17 30 17 1 2 3 4 5 6 7 8 9 1 2 3 4 refers to the auto shutdown temperature If the room temperature exceeds this value the LT1 will shut the dimming output and close the WRN dry connect also disconnect EMI1 and close EMI2 Touch SET MODE 11 to choose the output mode T...

Страница 10: ...he same as the zone shown here then the EMI1 contact will be open and the EMI2 contact will be closed Touch this field 4 to select temperature display for that zone Celsius or Fahrenheit This setting is made the same way in Zone B Touch this field 5 to set temperature limit value 1 T Limit 1 Valid entries are 50 104 Fahrenheit and 10 40 Celsius This setting is made the same way in Zone B Touch thi...

Страница 11: ...o dimming temperature Auto dimming of the output of corresponding zone as setting Wait for the temperature to drop to at least 2 C lower than theT Limit 1 value Auto shutdown when temperature is over the limit valueT Limit 2 The temperature of Zone A or Zone B is over the set value ofT Limit 2 auto shutdown temperature Auto shutdown of the output of corresponding zone Wait for the temperature to d...

Страница 12: ...ied warranty lasts or the exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the XTC1100 covered under this warranty if it is returned to the original place of purchase To request warranty service please return the XTC1100 with original sales receipt and original packaging to your place of ...