2
THE PHANTOM BALLAST
COMMERCIAL DE
is an ideal ballast choice
for efficient growing. It was created with state-
of-the-art microprocessor technology to utilize
the industry’s double-ended 1000W HPS lamps.
It operates on a 240V, 50/60 Hz power supply.
WARNINGS
• Use this ballast in greenhouses or indoor
applications only. Position it in an area away
from excessive heat or contact with liquids.
• This ballast does not rely on the luminaire
enclosure for protection against accidental
contact with live parts.
• For remote operations, use this ballast with a
maximum lamp cord of 30 feet.
• Disconnect the ballast from the power supply
before performing any maintenance, lamp
changes, or other modifications.
• Contact the retailer or distributor for service
if the ballast does not work after confirming
the power connection, output connection,
and bulb operation.
• Opening the ballast will void the warranty.
• Lamps with built-in ignitors will not work
with this ballast. Not for use with external
ignitors.
ALWAYS DISCONNECT BALLAST’S
POWER CORD BEFORE MOVING
THE UNIT OR CHANGING LAMPS.
INSTRUCTION MANUAL
Model
Main
Voltage
Operating Voltage
Range
Max Input
Power
Output Power Settings
Power
Factor
Ignitor
Voltage
THD
CF
ta
tc
PHB3015
240V
215-265V
1224W
Super/100%/75%/60%
> 0.98
4.0 KV
< 8%
1.414-1.6
40°C/104°F
70°C/158°F
Model
Imax
240v
Super Boost
240v
100%
240v
75%
240v
60%
240v
PHB3015
5.2
5.1
4.4
3.4
2.7
ELECTRICAL SPECIFICATIONS
INPUT AMPERAGE REFERENCE
BALLAST LED STATUS INDICATORS
STATUS
DIMMING BUTTON
SELECTED POWER LED
Warm Up
On
Slow Flash
Normal Operation
On
On
Stand By
Slow Flash
Slow Flash
Ballast Fault
Off
Off
Lamp Fault
Off
Rapid Flash
End of Life Lamp Indicator
Rapid Flash
Off
Connection Error
Flash x 1
Off
High Impact Voltage
Flash x 2
On
Low Impact Voltage
Flash x 3
On
Over Temperature
Flash x 4
On
Содержание PHANTOM Commercial DE PHB3015