INSTRUCTION MANUAL
www.Hydrofarm.com
4
INSTALLATING THE AIR CONDITIONER
Before you begin, determine where to install the air
conditioner. If you are using the included window kit, the
location must be near a window. Otherwise, we recommend
three to four feet of separation between the intake and
exhaust holes. The location must also have a power outlet
(we recommend running the unit on a dedicated 15A circuit
if possible). Be sure to maintain at least 12 inches (30 cm) of
clearance around the unit at all times as shown in Figure 1.
NOTE: Do not attempt to operate this unit without properly
ventilating it, as this will not work to cool the room and will
void the warranty. The exhaust and intake ducts must be
routed outside the room to the exterior of the structure.
Window Slider Kit Installation
The window slider kit can be installed in a window that
opens horizontally or vertically; the installation process is the
same for both. Before installing the window slider kit, make
sure your window meets the minimum and maximum size
requirements shown Figure 2.
1. Clear and clean the windowsill where you will install the
air conditioner.
2. Open window and attach window kit to window.
3. Attach the oval fixing clip to the window unit kit.
4. Expand the first exhaust hose to its full length.
5. Twist both ends of the exhaust hose, fitting one end into
the square fixing clip and one end into the flat fixing clip.
6. Repeat steps 4 and 5 for the second exhaust hose.
7. Attach the exhaust hoses to the bottom holes on the back of the unit and the other openings on
the window unit kit.
8. Close the window so it that it firmly closes on the window unit kit.
9. Insert the power cord into a grounded AC 120V/60 Hz receptacle.
10. Press the ON/OFF button to turn on the air conditioner.
8
Operation Introduction
Before starting operations in this section:
1) Find a place where there is power supply nearby.
2) As shown in Fig.5 and Fig.5a, install the exhaust hose, and adjust the window position well.
Please delete the singe duct unit from the image below. We only need to keep dual duct.
Fig.5 Fig.5a
12"
(30 cm)
12"
(30 cm)
13
Fig.9
Maintenance Explanations
Declaration:
1) Before cleaning, be sure to disconnect the unit from any electric supply outlet;
2) Do not use gasoline or other chemicals to clean the unit;
3) Do not wash the unit directly;
4) If the conditioner is damaged, please contact the dealer or repair shop.
Figure 2
Figure 1
12
Fig.7
2.
Introduction to Exhaust Hose Installation
Fig.8
A) Temporary installation
1.
Twist both ends of the exhaust hose into the square fixing clip and the flat fixing clip.
2.
Insert the square fixing clip into openings at back of the air conditioner (see Fig.9).
3.
Put the other end of the exhaust hose to the near windowsill.
Window Slider Kit Installation
The installation manner of window slider kit is mostly in “horizontal” and “vertical”, No much
difference in actual process.
As shown Fig.9, check the min. and max. size of the window.