background image

PUMP DIAGRAM AND PARTS LIST

Key

Part #

Description

1

10006700

Pump body

2

10011702

Rotor assembly
a. wire spring
b. rotor core
c. roller with axle

3*

Tubing: 4 cc with
grease & cable ties

10016008

Viton (optional)

10016007

Norprene (standard)

4

10006601

Pump cover

5

Screws:

10005201

short

10005202

long

* If changing pump tube material, use

same material for securing drum tube:
Securing pieces are: Viton --
10006302, Norprene -- 10006206
(2 each required).

2

a

b

c

4

3

1

Key

Part #

Description

1

10069135

Lock replacement kit

2

10069136

Timer replacement kit

3

10069103

Timer cover (clear)

4

10006103

Motor/gearbox

5

10069108

Wire harness*

6

10069137

Door with lock

7

10069138

Inner body with wiring

* Black wire goes to  motor terminal

that is marked with a red dot.

NOT SHOWN:

10016401

Tube connector barb kit

10016201

Drum tube kit -- Norprene

10016202

    "        "    "  -- Viton

10012301

Polyethylene tubing -- 1/4" O.D. x 20 ft.
Complete pump kits:**

10016807

4cc Norprene

10016808

4cc Viton

10016500

Cable ties (25)

10069110

AC adaptor

10069109

“D” cell battery holder

2

3

4

5

6

1

7

5

SYSTEM DIAGRAM AND PARTS LIST

Page 6

Содержание AutoDose 1060

Страница 1: ...rect discharge away from you or other persons or into approved containers dispense cleaners and chemicals in accordance with manufacturer s instructions Exercise CAUTION when maintaining your equipment equipment clean for proper operation protective clothing and eyewear when working in the vicinity of all chemicals filling or emptying equipment or changing tubes re assemble equipment according to ...

Страница 2: ...through to allow the tubing to pass into the pipe Wrap the injection fit ting once with sealing tape Teflon and screw in the injection fitting Tighten to provide a positive seal 8 Determine where the discharge tube will be secured to walls tables etc Cut tubing the appropriate length for such installation Connect the tubing to the injection fit ting Be sure the tubing will be out of the way of tra...

Страница 3: ...rate of a little more than 3 5 ounces per minute After the first few running hours the dispense rate will be approximately 3 5 ounces per minute and remain close to that for the balance of the practical battery life 40 total running hours The minimum dispensing time is one minute If a minimum dispense of less than 3 5 ounces is desired inquire about smaller capacity tubes 1 See the instructions fo...

Страница 4: ...wing programs does not change the settings but you can change the program while you are reviewing it by using the 1 7 h and m buttons If you are reviewing a program when a programmed on event should take place the motor will not start until you switch the unit back to automatic In the case of an off event the dispenser will not stop until you switch the timer back to automatic mode 7 To change a p...

Страница 5: ...event pumping 10 Place a dab of Tube Lube on the lower roller as shown Further lubing during operation is not needed 11 Replace the clear cover and install the two short screws into the brass inserts in the pump body 12 Put a cable tie on the inlet tube stem left side as viewed from front just below the pump housing This will prevent the tubing from walking through the pump as the pump operates 13...

Страница 6: ...uired 2 a b c 4 3 1 Key Part Description 1 10069135 Lock replacement kit 2 10069136 Timer replacement kit 3 10069103 Timer cover clear 4 10006103 Motor gearbox 5 10069108 Wireharness 6 10069137 Door with lock 7 10069138 Inner body with wiring Black wire goes to motor terminal that is marked with a red dot NOTSHOWN 10016401 Tube connector barb kit 10016201 Drum tube kit Norprene 10016202 Viton 1001...

Страница 7: ...illhelptoprovidetheproperdosingbyprovidingamoreconsistentpumpingrate USEONLYALKALINEBATTERIES CAUTION ALWAYSTURNTHEMODESWITCHTOTHE O POSITION OFF BEFORECHANGINGANYBATTERIES Tube Selection Guide TUBE DRAIN TREATMENT TYPE Viton Solvents Acids Norprene Bacterias Enzymes Detergents DispenserSpecifications PUMP Flow rate 100 cc approx 3 5 oz min Tube Model 1060 1070 1080 Norprene Models 1065 1075 1085 ...

Страница 8: ...12 03 Centerline of cabinet T O P CENTER DRILL AT THESE POINTS TEMPLATE FOR WALL MOUNTING DISPENSER Page 8 ...

Отзывы: