Troubleshooting Chart:
*
In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that
are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution).
To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner.
Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit.
Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then
flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into
concentrate.
1. No discharge
a. No water
a. Open water supply
b. Magnetic valve not functioning
b. Install valve parts kit
c. Excessive water pressure
c. Install regulator if water pressure
exceeds 4.3 Bar (flowing)
d. Eductor clogged
d. Clean* or replace
2. No concentrate draw
a. Clogged foot valve
a. Clean or replace
b. Metering tip or eductor has
b. Clean (descale)* or replace
scale build-up
c. Low water pressure
c. Minimum 1.76 Bar (flowing) is
required to operate unit correctly
d. Discharge tube(s) not in place
d. Push tube firmly onto eductor
or flooding ring missing from
hose barb; ensure inner discharge
inner discharge tube
tube is installed and has flooding ring
e. Concentrate container empty
e. Replace with full container
f. Inlet hose barb not screwed
f. Tighten, but do not overtighten
into eductor tightly
g. Clogged water inlet strainer
g. Disconnect inlet water line and clean
strainer
h. Selector out of position
h. Ensure selector is in position desired
3. Excess concentrate draw
a. Metering tip not in place
a. Press correct tip firmly into barb on
eductor
b. Chemical above eductor
b. Place concentrate below the eductor
4. Failure of unit to turn off
a. Water valve parts dirty or
a. Clean* or replace with valve parts kit
defective
b. Magnet doesn't fully return
b. Make sure magnet moves freely
c. Push button stuck
c. Remove button and clean cabinet/
button to remove any dirt lodged in
slide recess
5. Excess foaming in discharge
a. Air leak in pick-up tube
a. Put clamp on tube or replace tube if
brittle
b. Inner discharge tube not in place
b. Install inner discharge tube
6. Water discharge from air
a. Restricted discharge hose
a. Make sure discharge tube is not
vents on eductor
immersed, kinked or elevated. Ensure
there is no liquid in the discharge tube
when beginning to operate dispenser
b. High water pressure
b. Install pressure regulator if flowing
water pressure exceeds 4.3 Bar
Solution
Cause
Problem
10082112
Hydro Systems
Europe Ltd, Unit 3 The Sterling Centre, Eastern Road, Bracknell, Berks. RG12 2PW U.K.
Tel: +44 (0)1344 48 88 80
Fax: +44 (0)1344 38 88 79
www.hydrosystemseurope.com