Hydro AccuDose 3874GBA-2 Скачать руководство пользователя страница 2

4 LPM

14 LPM

Tip Colour

APPROXIMATE DILUTIONS

AT 2.86 BAR FOR WATER-THIN PRODUCTS (1.0 CP)

Orifice

Std. Drill

Size

Number)

Ratio (per Eductor Flow)

No Tip

.187

(3/16)

3:1

6.5:1

Grey

.128

(30)

3:1

6.5:1

Black

.098

(40)

3:1

7:1

Beige

.070

(50)

4:1

10:1

Red

.052

(55)

5:1

16:1

White

.043

(57)

7:1

20:1

Blue

.040

(60)

8:1

24:1

Tan

.035

(65)

10:1

30:1

Green

.028

(70)

16:1

45:1

Orange

.025

(72)

20:1

56:1

Brown

.023

(74)

24:1

64:1

Yellow

.020

(76)

32:1

90:1

Aqua

.018

(77)

38:1

128:1

Purple

.014

(79)

64:1

180:1

Pink

.010

(87)

128:1

350:1

Metering Tip Selection:

The final concentration of the dispensed solution is
related to both the size of the metering tip opening and
the viscosity of the liquid being siphoned. For water-
thin products, the chart at left can be used as a
guideline. If product is noticeably thicker than water,
consult the Measurement of Concentration Procedure
below to achieve your desired water-to-product ratio.
Because dilution can vary with water temperature and
pressure, actual dilution achieved can only be ascer-
tained by using the Measurement of Concentration
Procedure. The clear, undrilled tip is provided to permit
drilling to size not listed should you need a dilution ratio
that falls between standard tip sizes.

NOTE:

 A 4 LPM eductor is grey; a 14 LPM eductor is

yellow. Refer to parts diagram if unfamiliar with names
of system components.

Measurement of Concentration:

You can determine the dispensed water-to-product
ratio for any metering tip size and product viscosity. All
that is required is to operate the primed dispenser for
a minute or so and note two things: the amount of
dispensed solution, and the amount of concentrate
used in preparation of the solution dispensed. The water-to-product ratio is then calculated as follows:

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn

Amount of Concentrate Drawn

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test does not yield the desired ratio, choose a
different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact your
concentrate supplier for further information on these alternative methods and the materials required to perform them.

AccuDose Parts Diagram:

4

6

7

2

3

1

5

1

238100

Strainer washer

2

10082835 Swivel collar

3

10082806 Swivel stem
10075950 O-ring (stem /valve connection)

4

10075925 Pipe plug

5

10080710 Button, dark grey (standard)
10080711 Button, sky blue
10080712 Button, red
10080713 Button, green
10080714 Button, light grey
10080715 Button, yellow

6

10080894 Cabinet Set

7

10020700 Selector valve grommet
10020900 Back up ring for grommet

Description

Part No.

Key

Содержание AccuDose 3874GBA-2

Страница 1: ...REMEMBER TO CHECK FOOT VALVE STRAINERS PERIODICALLY FOR CLOGGING CLEAN IF NECESSARY 7 A short discharge tube is used with a 4 LPM grey eductor Model 3875GBA 2 minimum tube length is 20 cm for correct operation A longer tube 1 2m is used with a 14 LPM yellow eductor Model 3874GBA 2 Slide end of tube over inner discharge tube and onto eductor discharge outlet The hose hook supplied with Model 3874GB...

Страница 2: ... is grey a 14 LPM eductor is yellow Refer to parts diagram if unfamiliar with names of system components Measurement of Concentration You can determine the dispensed water to product ratio for any metering tip size and product viscosity All that is required is to operate the primed dispenser for a minute or so and note two things the amount of dispensed solution and the amount of concentrate used ...

Страница 3: ...arge tube b 10070470 14 LPM inner discharge tube 13 a 10064794 4 LPM outer discharge tube b 10077315 14 LPM outer discharge tube 14 10080720 Hose hook dark grey std 10080721 Hose hook sky blue 10080722 Hose hook red 10080723 Hose hook green 10080724 Hose hook light grey 10080725 Hose hook yellow Hose hook provided with Model 3874GBA 2 only 15 10080920 Selector valve replacement kit e Suction stub ...

Страница 4: ...nsure inner discharge inner discharge tube tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer h Selector out of position h Ensure selector is in position desired 3 Excess concentrate draw...

Отзывы: