HOT SERIES 
    (High Output Temperature) 

 

 

Geothermal Water to Water Heat Pump 

 

R-134A Refrigerant 

 

2 Ton to 20 Ton Single Speed 

 

 

 

 

 

 

 

Customer Manual 

Содержание HOT Series

Страница 1: ...HOT SERIES High Output Temperature Geothermal Water to Water Heat Pump R 134A Refrigerant 2 Ton to 20 Ton Single Speed Customer Manual ...

Страница 2: ...Customer Manual 5 2 3 2 ...

Страница 3: ...Customer Manual 5 2 3 3 Change is in the Air You are about to experience a level of comfort and efficiency that many people don t even know exist ...

Страница 4: ...eothermal heat pumps are known for being GREEN however green usually means giving something up In your case not only will you be helping the environment now and for the future you are providing yourself with the most comfortable indoor environment available today It is not often you can make an impact on others by providing for yourself ...

Страница 5: ...ngth one way ____ft Pond Loop of Circuits ______ Total length per Circuit ____ft Depth where sunk _____ft Other__________________________ Use this area to make a rough drawing of the loop in relation to the home One block equals ________ feet Notes ____________________________________________________________________________ __________________________________________________________________________...

Страница 6: ... T A C T IN F O R M A T I O N 8 1 0 T R A N S P O R T A T I O N S T O R A G E 8 2 0 E L E C T R I C A L H A Z A R D W A R N I N G S 8 3 0 P R E V E N T A T I V E MA I N T E N A N C E 9 4 0 C O N T R O L S A N D T O U C H SC R E E N D I S P L A Y 1 0 ...

Страница 7: ...SUPPLY RIGHT RETURN LEFT SUPPLY WATER SOURCE W OPEN LOOP WELL WATER C CLOSED LOOP T COOLING TOWER X IF NON APPLICABLE STRIP HEAT XXX NO STRIP HEAT 005 5KW 010 10KW 015 15KW 020 20KW OR TOTAL KW REFRIGERANT 1 R410A 2 R22 3 R134A 4 R407C X IF NON APPLICABLE Microprocessor X TERMINAL STRIP 1 GEORGIA CONTROL HYDRO TEMP 2 AUTOMATED LOGIC 583 3 AUTOMATED LOGIC 6126 4 END USER DDC VOLTAGE PHASE 1 208 230...

Страница 8: ... note on the delivery slip acknowledging the damage During freezing conditions special consideration should be made to prevent unit damage If a unit is taken to the job site or put in storage anti freeze will need to be pumped into the water coils to prevent freezing Failure to do this will void warranty 2 0 Electrical Hazard Warnings THE FOLLOWING IS A GENERAL WARNING STATEMENT WHICH SHOULD BE RE...

Страница 9: ...AMAGE TO THE UNIT DAMAGE TO THE UNIT CAUSED BY FAILURE TO MAINTAIN PROPER ANTIFREEZE LEVELS ISNOT COVERED UNDER WARRANTY Open loop systems require well water to be pumped through the system For this reason Hydro Temp recommends the installing dealer to install isolation valves and a water strainer on the entering water line feeding water to the Hydro Temp system Be aware of the location of these c...

Страница 10: ...om running without turning off the power Caution MUST be taken when opening the unit for service work as the master switch does not disconnect power The unit is still powered with the master switch off This switch is useful when needing to shut down the system for filter replacement or system operation is not needed but thermostats are to remain powered 4 1 Thermostat Tank sensor Most water to wat...

Страница 11: ...displayed at the bottom will be the control program number and program version 4 1 6 Protostar Equipment Touch Display Settings Screen The Settings screen allows the end user a way to adjust system set points Net Master should always be on for normal system operation Turning this off will disable the system Hot water Start The temperature the system will kick on to make hot water Hot water stop Th...

Страница 12: ...ouch Display Detailed status Screen The detailed status screen shows the status of all input outputs and system safeties 4 1 8 Protostar Equipment Touch Display Compressor runtime screen The run time screen shows the time in hours the compressor has ran ...