STEP 3: Install the wall-mounted transformer

1.   Plug the wall transformer into an AC outlet.
2.  Plug the barrel adapter into the Taurus CP-300 power connector at the 

bottom of pump unit.

The green LED on the pump will turn on, indicating power and the remote 
LEDs will flash the firmware revision.

NOTE:

 Use only the transformer specified from the manufacturer to  

ensure proper operation. Usage of transformer must conform to local  
laws and codes.

STEP 4: Prime the pump unit

1.  Press and hold the START button on the remote unit for 10 seconds to 

start priming.

2.  When the tubing is free of air, release the button to stop priming.

Installation

Step 3.1: Plug wall transformer into 

AC outlet

Step 3.2: Plug adapter into pump

Step 4.1: Press and hold START 

button for 10 seconds

!

WARNING 
ADVERTENCIA: 

 

Always verify power source 

voltage with volt meter.

Siempre verifique la 

alimentación de corriente con 

un voltímetro.

Содержание Taurus CP-300

Страница 1: ...cal and plumbing codes El equipo CP 300 debe ser instalado sólo por técnicos calificados y de acuerdo con todas las normas de plomería y eléctricas que apliquen Remote Wall Mount Kit P N 13 08607 00 Wall Mounted Transformer 100 240 VAC P N 10096229 This Quickstart Guide P N 20 09208 00 General Specifications Feature Range Pump delay time 0 30 min 5 min increments Pump run time 0 20 min real time P...

Страница 2: ... discharge tubing Supply Tubing 1 Cut tubing and route from product container to intake left pump tube Slip tubing through compression nut into fitting and tighten 2 Place other end of tubing into the product container Discharge Tubing 1 Cut tubing and route from discharge location to outflow right pump tube 2 Slip tubing through compression nut into fitting and tighten Installation Step 1 1 Slide...

Страница 3: ...only the transformer specified from the manufacturer to ensure proper operation Usage of transformer must conform to local laws and codes STEP 4 Prime the pump unit 1 Press and hold the START button on the remote unit for 10 seconds to start priming 2 When the tubing is free of air release the button to stop priming Installation Step 3 1 Plug wall transformer into AC outlet Step 3 2 Plug adapter i...

Страница 4: ... remote button while the pump is in delayed start mode or while the unit is dispensing NOTE Please refer to the following instructions for more information on LED indicator functionality START button The START button activates the pump and is also used in conjunction with the hidden PROG SELECT button to program the pump PROG SELECT button The PROG SELECT button is located under the water drop ico...

Страница 5: ...ns is described below Programming the Start Delay Time 1 Once in programming mode press the PROG SELECT button once The yellow LED indicator will illuminate 2 With the yellow LED illuminated press the START button once for every five minute increment delay you wish to add Each press is confirmed by a yellow LED flash Please refer to the table below to determine the number of presses needed for you...

Страница 6: ...eriod 1 Once the pump Run Time has been programmed press the PROG SELECT button again The red LED indicator will illuminate to indicate you can program a Lockout Period 2 With the red LED illuminated press the START button once for every five minute lock out period you wish to add Each press is confirmed by a red LED flash Please refer to the table below to determine the number of presses needed f...

Страница 7: ...he START button for 2 seconds All three LED indicators will illuminate to indicate the programmed settings have been saved A program review will be conducted as follows Program Feature Review Indicator Start Delay Time The yellow LED will turn on and flash for each five minute increment for which the Start Delay Time was programmed no flash indicates 0 pump Start Delay Time Run time The green LED ...

Страница 8: ...onds while powering up the unit All three LED indicators will flash on and off twice to confirm that factory defaults have been restored Optional Spare Parts Ref Part Description 1 13 08602 06 Pump Cover Teal screw included 2 13 06396 00 Pump Spinner 3 13 06399 10 Pump Tube Standard 1 4 Detergent EPDM 10 pk 13 06395 10 Pump Tube 1 4 Rns EPDM 10 pk 13 06395 30 Pump Tube 1 8 Rns EPDM 10 pk 4 13 0872...

Страница 9: ...es b and products that have a normal life shorter than one year or c failure in performance or damage caused by chemicals abrasive materials corrosion lightning improper voltage supply physical abuse mishandling or misapplication In the event the Products are altered or repaired by BUYER without SELLER S prior written approval all warranties will be void NO OTHER WARRANTY ORAL EXPRESS OR IMPLIED I...

Отзывы: