8
Page
•
Installa
tion
and service must be perf
ormed
by a
qualifi
ed installer (f
or
example, a
licensed plumber
or
gas
fitt
er),
othe
rwise
the
warranty will be v
oid.
•
The
installer (licensed pr
o
f
essional)
is r
esponsible
f
or
the
c
or
rect installa
tion
of
the micro-boiler and for compliance with all national, state/provincial, and local
c
odes.
•
The
manufacturer
does
not
rec
ommend
installing
the micro-boiler in a pit or
lo
ca
tion
whe
re gas and water can accumulat
e.
•
Do not have the vent terminal poin
ting
toward any opera
ting
window, door, or
opening into a building.
•
Do not install the micro-boiler next to any source of airborne debris, such as a
clothes dryer and a vent that can cause debris to be trapped inside the combus
tion
chamber, unless the system is direct-vented.
•
The
manufacturer
does
not
rec
ommend
installing
the
micro-boiler in an attic due
t
o
safety
issues.
If you install the micro-boiler in an a
ttic:
•
Make sure the micro-boiler will have enough combus
tion
air and proper
ven
til
a
tion
.
•
Keep the area around the micro-boiler clean. When dust collects on the
flame
sensor, the micro-boiler will shut down on an error code.
•
Place the micro-boiler in a loca
tion
that provides easy access for service and
maintenance.
•
A drain pan, or other means of prot
ection
against water damage, is required to
be installed under the micro-boiler in case of leaks.
•
It is recommended to direct vent the heater.
WARNING
•
Damage caused by water quality is
not
c
o
vered by
the
warranty
.
•
Only potable water or potable water / glycol mixtures can be used with this
micro-boiler. Do not introduce pool or spa water, or any chemically treated
water into the micro-boiler.
•
Water hardness levels must not exceed 7 grains per gallon (120 ppm) for single
family domes
tic
applica
tions
or more than 4 grains per gallon (70 ppm) for
all other types of applica
tions
. Water hardness leads to scale forma
tion
and
may a
ff
ect / damage the micro-boiler. Hard water scaling must be avoided or
controlled by proper water treatment.
•
Water pH levels must be between 6.5 and 8.5
•
Well water must be treated.
•
Do not install the micro-boiler where water, debris, or
flammable
vapors may get
into the
flue
terminal.
•
Although the micro-boiler is designed to operate with minimal sound,
th
e
manufacturer
does
not
rec
ommend
installing
the micro-boiler on a wall adjacent
t
o
a bedr
oom,
or
a r
oom
th
at is intended f
or
quiet study
or
medita
tion,
etc
.
•
Locate your boiler close to a drain where water leakage will not do damage to
surrounding areas. As with any
fluid
hea
ting
appliance, the poten
tial
for leakage
at some
time
in the life of the product does exist. The manufacturer will not be
responsible for any water damage that may occur. If you install a drain pan under the
micro-boiler, ensure that it will not restrict the combus
tion
air
fl
ow .
CAUTION
Содержание HS120CON-LP