32
3.2 Heat pump placement
The unit will work properly in any desired location as long as the following three items are present:
1. Fresh air
–
2. Electricity
–
3. Swimming pool filters
The unit may be installed in virtually any
outdoor
location as long as the specified minimum distances to other
objects are maintained (see drawing below). Please consult your installer for installation with an indoor pool.
Installation in a windy location does not present any problem at all, unlike the situation with a gas heater (including
pilot flame problems).
ATTENTION:
Never install the unit in a closed room with a limited air volume in which the air expelled from the unit
will be reused, or close to shrubbery that could block the air inlet. Such locations impair the continuous supply of
fresh air, resulting in reduced efficiency and possibly preventing sufficient heat output.
See the drawing below for minimum dimensions.
3.3 Distance from your swimming pool
The heat pump is normally installed within a perimeter area extending 7.5 m from the swimming pool. The greater
the distance from the pool, the greater the heat loss in the pipes. As the pipes are mostly underground, the heat
loss is low for distances up to 30 m (15 m from and to the pump; 30 m in total) unless the ground is wet or the
groundwater level is high. A rough estimate of the heat loss per 30 m is 0.6 kWh (2,000 BTU) for every 5 ºC
difference between the water temperature in the pool and the temperature of the soil surrounding the pipe. This
increases the operating time by 3% to 5%.
3.4 Check-valve installation
Note: If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential to protect the heat pump
against excessively high chemical concentrations which may corrode the heat exchanger. For this reason, equipment
of this sort must always be fitted in the piping on the
downstream
side of the heat pump, and it is recommended to
install a check-valve to prevent reverse flow in the absence of water circulation.
Damage to the heat pump caused by failure to observe this instruction is not covered by the warranty.
Содержание 7029988
Страница 2: ...Index Spis treści CO2 Regulation EU Regulacje CO2 EU 1 3 Polski 4 27 English 28 50 Deutsch 51 72 ...
Страница 8: ...6 2 Wymiary mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Страница 9: ...7 Model Hydro S 12 ...
Страница 24: ...22 8 Schemat budowy pompy 8 1 Widok urządzenia rozebranego Model Hydro S 5 ...
Страница 32: ...30 2 Dimension mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Страница 35: ...33 3 5 Typical arrangement Note This arrangement is only an illustrative example ...
Страница 40: ...38 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Hydro S 5 Hydro S 8 Hydro 10 ...
Страница 47: ...45 8 Exploded Diagram 8 1 Exploded Diagram Model Hydro S 5 ...
Страница 55: ...53 2 Ausmaße mm Model Hydro S 5 Model Hydro S 8 Hydro S 10 ...
Страница 58: ...56 Garantie gedeckt 3 5 Typische Anordnung Anmerkung Diese Anordnung ist nur ein illustratives Beispiel ...
Страница 69: ...67 8 Explosionszeichnung und Wartung 8 1 Explosionszeichnung Hydro S 5 ...
Страница 75: ......
Страница 76: ...A0111HYSR302 ...