Mist-n-Go User Manual
www.HydromistUSA.com
15
7.
Maintenance
7.1
Periodic Check and Inspection
Items
Interval
Before
Operation
50hr
100hr
200hr
300hr
Main Components
Check All Fittings are Tight
◆
◆
Check Water Lines for Leakage
◆
◆
Check Pump for Oil Leakage
◆
◆
Inspect Top and Bottom Covers
◆
◆
Hose/Pipe/Rings
Check Connectors and Hoses for
Damage or Loose Fittings
◆
◆
Check and Clean Inlet Water Filter
◆
◆
Check Nozzles for Leaks or
Blockage
◆
◆
◆
◆
◆
Electrical
Check Power Supply for Damage
◆
◆
Check Electric Cord for Damage
◆
◆
Pump
Pressure Regulator
◆
Check Oil: Quality and Quantity
◆
◆
◆
Change Oil
◆
(Only for
the first
time)
◆
Pressure Relief Valve
◆
Oil Seals
◆
Plungers
◆
Motor
Check the Rubber Motor Mounts
◆
The above maintenance schedule is for operation at normal conditions.
Varying environmental conditions may cause excess wear on the pump or
misting system components, and your equipment may need to be
serviced more frequently.