Heat Pump main unit disassembly   

 
If want to check and maintain the top main parts of the unit, should disassembly the cover of the unit, 
follow the below steps (Fig.5, 6) to process.   
 
 

 

 
           

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(Fig.5)                                                                    (Fig.6)   

 
 
1.  Move  up  the  control  panel  and  its  components-1(including  control  panel

decorative  panel, 

decorative aluminum profile

decorative strip) vertically 15-20mm, then pull it out horizontally to 

separate hook A-2 from hook A-3 until exposed butt splice connector; 

2. Disconnect control panel with butt splice connector

 

3. Remove all screws-5 from the bottom of the top cover. 
4. Release the power line from the top cover of fixed terminal, to prevent the power line stuck when 
move up the top cover. 
5. Finally, remove the block objects (e.g. air ducts etc.) from the air inlet /outlet, holding both sides of 
the top covers and move it up. 
 
 

 
 
 

6

4

5

3

3

2

2

ON/OFF

CLOCK

TIMER

MODE

1

Содержание Aqua-Man 260L

Страница 1: ... your power bill with Hydro Hero ENERGY EFFICIENT SOLUTIONS EES the heat pump specialists f 0800 EES 123 p 09 973 5993 e info eesnz co nz ENERGY EFFICIENT SOLUTIONS EES the heat pump specialists POWERED BY ...

Страница 2: ...kW Rated input output electric kW Max current amps Max input power kW Rated output water temp Power supply V COP at 20 EN255 3 COP at 15 EN255 3 COP at 7 EN255 3 Refrigerant Noise level dB A Air flow m3 h Tank construction Dimensions mm Pressure rated max MPa Gross weight KG Compressor specification Warranty heat pump Cylinder 260L 0 7kW 2 8kW 2kW 2kW 15 amps 3 3kW 55 70 220V 4 21 3 88 2 95 R134a ...

Страница 3: ...Hydro Hero Heat Pump Water Heater INSTRUCTIONS ...

Страница 4: ...Water Inlet Drainage Hole Screen Panel Evaporater Magnesium Anode Hole Electric Heater Cover Electric Heater Hole Decoration Bar Electric Board Compressor Tank Cover Decoration Panel Left Right Decoration Bar Condensate Drain Hole Circulation Water Hole Wiring Hole Power Line Temp Sensor Tube Hole Circulation Water Hole Hot Water Outlet ...

Страница 5: ...Operation RI FRQWUROO panel ...

Страница 6: ...过55 时 显示屏上 高温 提示亮 Set Temperature High Temperature Alarm Auxiliary Heater Status HTG Heating DEF Defrost WARM Keep warm Working Mode Time adjustment Time Timer On Timer Off Timer Period Water Temperature Temperature Gradient Note When the water temperature exceeds 55 the indicator light on display ...

Страница 7: ...r F21 Compressor start delay 0 10 3 minute F28 Econ mode turn on or off electric heater 0 1 1 F29 Heat pumps working or not in heater mode 0 1 1 Defrost F31 Defrost start temp 20 20 2 C F32 Defrost finish temp 0 50 25 C F33 Defrost start time 1 999 30 minute F34 Max defrost time Off 1 99 5 minute Alarm F50 Low pressure alarm mode 0 2 2 F51 Auto resume times of low pressure alarm 0 10 3 time F52 Re...

Страница 8: ...lve EEV F70 EEV opening query 0 480 F71 EEV control mode 0 2 0 F72 Manually set EEV opening 100 480 350 F73 Set EEV superheat degree 15 15 5 F74 Set EEV discharge temp 85 110 92 F79 Return gas temp System Setting F80 Password OFF 0001 9999 4321 OFF means no password Set 0000 to clear password F85 Display sterilization total time hour Testing F98 Force defrosting refrigeration Control panel display...

Страница 9: ... temp is too high 2 Change the Electric heater A7 Exhaust temperature too high 1 Lack of refrigerant 2 Mix with air in system 3 Lack of lubricating oil 1 Supply refrigerant 2 Re vacuumizing and fill in refrigerant 3 Change the lubricating oil of compressor A8 Condensate drain hole blocked 1 condensate pipe blocked 2 Machine drain hole blocked 1 Check condensate pipe is blocked or not 2 Check machi...

Страница 10: ...ation for a long time there may have condensation water hereabout the air outlet or pipe especial in humidity weather this is a normal phenomenon use a dry washcloth to clean it or by air dry 6 The advance setting parameters of the operation panel has been set at the factory users no need to reset it the maintenance person should be carefully set if needed Maintenance and service 1 After carry and...

Страница 11: ...p vertically 15 20mm then pull it out horizontally to separate hook A 2 from hook A 3 until exposed butt splice connector 2 Disconnect control panel with butt splice connector 3 Remove all screws 5 from the bottom of the top cover 4 Release the power line from the top cover of fixed terminal to prevent the power line stuck when move up the top cover 5 Finally remove the block objects e g air ducts...

Страница 12: ... POWER SUPPLY YELLOW GREEN Transformer WATER TEMP SENSOR OPERATION PANEL ELECTRIC HEATER YELLOW GREEN 4 WAY VALVE FAN MOTOR YELLOW GREEN ELECTRIC HEATER PROTECTOR PRESURE PROTECTOR Electronic expansion valve AMBIENT TEMP SENSOR COIL TEMP SENSOR EXHAUST TEMP SENSOR RETURN GAS TEMP SENSOR N BXS HI LOW COMPRESSOR 5 RED 220V ...

Отзывы: