The Problem: Failure to communicate.
The Likely Solutions:
1) The programming pod’s battery is low or out of power or the Handheld Programmer
is low or out of power; replace battery.
2) You may have an incorrect actuator and/or program code. Connect the handheld
programmer via the cord, and set a new actuator code.
3) There might be a problem with a connection or solenoid. Perform an electrical
system check.
Special Notes:
The Pod’s internal memory lasts only 3 minutes. Any time the battery within the
Programming Pod dies, it is necessary to plug the Handheld Programmer directly into
the Pod and re-assign the Actuator ID and reprogram the Unit. While repeating the
programming steps is only a minor inconvenience, a proactive approach to battery
maintenance will serve to alleviate the frequency with which these steps must be
completed.
For all other programming questions, please refer to the Hydro-Guard® Programming
Guide. If the information you require is not available therein, please contact Hydro-
Guard® Customer Service at (877) 864-8500.