Page 17 of 24
HG-3 Unit Assembly
After disassembly put riser and ground plate assembly next to the internal assembly
Step 1
Install phone line through bottom plate into coupler nipple and install coupler.
Step 2
Install1/4” coil tube into relief valve.
Step 3
Install internal assembly into body, handles facing down. Go straight down until unit is
on male banjo coupling. Pull handles up to lock into place.
Step 4
Install riser and ground plate, lining up the 4 security bolts then tighten. Place O-Ring
over pipe and push into groove. Install yoke and the 2 7/16” bolts.
Step 5
Install diffuser, nuts, and washer.
Step 6
Install cover with 2 security screws.
Step 7
Turn on water supply and run a manual flush to check that everything is O.K.
Assembly complete.