Hydro-Force Power X Pro Spot MA51 Скачать руководство пользователя страница 10

 

10 

 

Section 

 
 
 
 
 
Troubleshooting –  
Power X Pro Spot Extractor 
 

 

Problem 

Cause 

Solution 

Machine not  

Building circuit breaker tripped. 

Reset breaker or move cord to other outlet 

turning on -  

Faulty power cord 

Replace cord  

No power 

Faulty switches or internal wiring 

Check wiring & test switches - Repair as needed * 

  

  

  

Solution  

Building circuit breaker tripped. 

Reset breaker or move cord to other outlet. 

Pump 

Faulty power cord 

Replace cord  

not running 

Faulty switches or internal wiring 

Check wiring & test switches - Repair as needed * 

  

Pump faulty 

Replace Pump (AP30) 

  

  

  

Low Solution 

Jet too large for pressure desired 

Check jet size & flow rates use smaller jets  

Pressure 
and/or 

Jet worn allowing too much flow 

Replace jet 

Pulsation 

Solution inlet filter plugged 

Clean or replace filter 

  

Hose from solution tank restricted  Repair or replace hose 

 

Heater Restricted with scale 
(MA51H Only) 

De-scale or replace the heater 

 

Pressure Relief valve stuck open 
(MA51H Only) 

Replace the pressure relief valve 

  

Pump intake hose or fittings 
leaking 

Repair or replace hose. Tighten clamps or replace fittings 

  

Solution tank empty 

Add water to tank - Check & repair auto fill assembly 

  

Pump faulty 

Repair or replace pump (AP30) 

  

Tool valve faulty 

Repair or replace valve 

  

Quick connects or hoses 
restricted 

Clean out or replace quick connects and/or hoses 

  

  

  

Can't connect 

Pressure in lines 

Turn off pump - Release pressure 

solution hose 

Quick connects faulty 

Replace quick connects (AH101B, AH102B) 

to machine 

Wrong style/size quick connects 

Replace quick connects to match connects on machine 

 

 

 

Heater not 

Faulty switches or internal wiring 

Check wiring & test switches - Repair as needed * 

 Heating 
(MA51H Only) 

Temperature Switch tripped 

Reset manual reset temperature switch. 

 

 Faulty temperature switches 

 Replace temperature switches on heater 

 

Faulty Heater 

Replace heater 

 

Flow too high for proper heating 

Use smaller jet or slow use of water 

 

Water Starting out too cold 

Heat water before filling tank – Maximum 120˚F 

  

  

  

*  To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by 

 

experienced service technicians. 

 

 

If you are not experienced in checking electrical wiring contact your nearest authorized service 

 

center to perform tests and repairs to wiring and switches. 

Troubleshooting 

Содержание Power X Pro Spot MA51

Страница 1: ... X Pro Spot Extractor MA51H Power X Pro Spot Extractor with Heat Operating Manual Power X Pro Spot Extractor Hydro Force 4282 South 590 West Salt Lake City UT 84123 801 268 2673 801 268 3856 FAX Revised 10 08 2014 ...

Страница 2: ...y 6 SECTION 2 Operation Procedures Electrical Supply 7 Water Supply Chemicals 7 Solution Vacuum Hoses 7 Starting System Switches 8 Shutdown Procedures 9 Troubleshooting 10 11 Solution Flow Path MA51 12 Solution Flow Path MA51H 13 Wiring Diagrams MA51 14 Wiring Diagrams MA51H 16 SECTION 3 Maintenance Technical Maintenance 18 Parts 21 o MA51 22 o MA51H 27 o Hoses Tool 34 Warranty 35 ...

Страница 3: ...e machine and to ensure that the equipment operates at its maximum performance level All users must read and understand this manual completely before operating the machine Always maintain this manual in legible condition adjacent to the Power X Pro Spot Extractor or place in a secure location for future reference Any questions pertaining to the operating or servicing of this unit should be directe...

Страница 4: ...r Draw 6 42 7 3 amps Power X Pro Spot Extractor with Heater Model MA51H Height 24 Length 21 Width 10 Weight 30lbs Solution Tank Capacity 3 gallon Recovery Tank Capacity 3 gallon Power Cord 20 foot 16 3 Solution Outlet 1 4 Male Quick Connect Solution Pump Flojet ET508224 HP pump 55 psi 0 37gpm Vacuum Motor AMETEK Lamb 4 8 Diameter Peripheral discharge Two Stage 87 7cfm 76 5 WC Heater 600 Watt Power...

Страница 5: ...llustrated in the sketch to the right Make sure that the machine is connected to an outlet having the same configuration as the plug No plug adapter should be used with this machine The power cord supplied with this machine is properly sized to handle the electrical load of this machine and properly grounded as described above Any extension cords used with this machine must be similarly sized and ...

Страница 6: ...chemical compatibility Contact your distributor or Hydro Force if you have questions regarding the compatibility of your chemicals with the machine Do not clean with solutions that are at temperatures above 100ºF Rinse the solution tank chemical system and pump with fresh water after each day s use Do not allow pump to run dry Always maintain adequate solution level to supply solution pump Solutio...

Страница 7: ...to a level approximately 4 inches from the top of the tank The water temperature should not exceed 120 F Measure and add the appropriate amount of the desired liquid chemical to the water in the solution tank The amount of chemical will vary depending on the type of chemical used the amount of water in the tank and the material being cleaned consult the chemical packaging for specific mixture rati...

Страница 8: ...teady check the hose from the solution tank to the pump and the filter screen for clogging kinks or restrictions Clean or replace hose and or filter and Turn switch ON Check the valve operation and the jet on the tool for flow restriction that can affect solution flow If you are having trouble with the pump refer to the trouble shooting guide or contact your distributor for advice or assistance On...

Страница 9: ... to release pressure from the hose before disconnecting solution hose Drain any remaining water from the solution tank and the recovery tank and dispose in sanitary drain Drain the recovery tank by pouring the water out of the vacuum barb Do not attempt to pour the water out the recovery tank hatch cover opening Do not use the same bucket to drain the tank that you use to fill the tank Remove the ...

Страница 10: ...e Tighten clamps or replace fittings Solution tank empty Add water to tank Check repair auto fill assembly Pump faulty Repair or replace pump AP30 Tool valve faulty Repair or replace valve Quick connects or hoses restricted Clean out or replace quick connects and or hoses Can t connect Pressure in lines Turn off pump Release pressure solution hose Quick connects faulty Replace quick connects AH101...

Страница 11: ...Repair or replace float shutoff Recovery tank damaged Replace recovery tank Tool won t Jet clogged Clean out or replace jet spray low or Inline filter clogged Clean out or replace filter if so equipped uneven spray Jet worn Replace jet Jet not aligned properly Re align jet Tool valve faulty Repair or replace valve Quick connects or hoses restricted Clean out or replace quick connects and or hoses ...

Страница 12: ...12 Solution Tank Outlet Quick Connect Denotes Water flow in pressure hose Denotes incoming water flow MA51 Solution Flow Path Pump AP30 ...

Страница 13: ...es Cold Water flow in pressure hose Denotes incoming water flow MA51H Solution Flow Path Pump AP30 Denotes Heated Water flow in pressure hose HEATER PRESSURE RELIEF VALVE Denotes Heated Water by pass flow from heater pressure relief CHECK VALVE ...

Страница 14: ...4 MA51 Wiring Diagram Standard Power Switch POWER CORD OLD STYLE SINGLE SWITCH PUMP VACUUM AV06 Pump Switch POWER CORD NEW STYLE DUAL SWITCH PUMP VACUUM AV06 Vacuum Switch YELLOW WHITE GREEN GROUND SCREW ...

Страница 15: ...on Pump Switch Vacuum Switch When the switch is turned to the ON position power is supplied to the solution pump motor and vacuum motor Power Cord Old Style Single Switch New Style Dual Switch Power Cord Vacuum Switch Solution Pump Switch ...

Страница 16: ...Pump Switch Heater Switch Vacuum Switch POWER CORD HEATER 600w VACUUM AV06 PUMP Manual Reset Hi Limit Temperature Switch 10 0814 B Auto Reset Temperature Control Switch 10 0814 HEATER ELEMENT PSA101500B New Style Heater Only GROUND SCREW ...

Страница 17: ...tor only When not using solution Extracting only do not turn this switch ON Heater Switch When the switch is turned to the ON position power is supplied to the solution heater only Always turn pump switch on first and be sure water is flowing to the tool before turning heater ON Turn heater off and spray tool for a minute to cool off heater before turning pump off When not using solution Extractin...

Страница 18: ... before testing or repairing switches or power cords Failure to do so may result in severe personal injury or death OPERATION INTERVAL Page CLEAN VACUUM SHUTOFF ASSEMBLY Daily After Each Job 19 RINSE OUT RECOVERY TANK Daily 19 FLUSH SOLUTION TANK AND PUMP Daily 19 CLEAN PUMP INLET FILTER Daily 19 DESCALING HEATER MA51H ONLY As needed 20 REMOVING BASE TO ACCESS HEATER MA51H ONLY As needed 20 STORAG...

Страница 19: ...the tank smelling better 1 Remove the recovery tank lid 2 Use a hose to rinse the dirt and debris out of the recovery tank 3 Spray the tank with a deodorizer or disinfectant 4 Replace the recovery tank lid 5 Dispose of the dirty water and debris FLUSH SOLUTION TANK AND PUMP 1 Pour one gallon of clean water into the solution tank Slosh the water around in the tank to clean tank and pour water out a...

Страница 20: ...f the Power X Pro Spot Extractor Storage Prep and Freeze Protection Procedures Your Power X Pro Spot Extractor must be protected from freezing Freezing can cause serious damage to the pump pump out auto fill float valve and any other component containing water If the Power X Pro Spot Extractor is transported or stored in freezing temperatures the following procedures should be performed 1 In a sep...

Страница 21: ...21 Parts Replacementpartsavailableforrepairof yourPowerXProSpotExtractor Section 3 Power X Spotter Pump AP30 Power X Spotter Vacuum Motor AV06 SOLUTION OUTLET 1 8 FPT SOLUTION INLET 1 8 FPT ...

Страница 22: ...70 Nipple 1 8 Hex 1 AH102B Quick Connect 1 4 Male 1 PAF03 Quick Connect 1 8 Male 1 10 0434 Threaded Hose for Spotter 2 5 NA0839 Barb Nylon Straight 1 8 NPT X 4 NA0840 1 8 Strainer for Spotter 1 AP30 Pump For Spotter 1 10 0301 L Bracket For Spotter 1 10 0435 Oetiker Clamp 5 10 0303 Roller Blade Wheel 2 10 0387 5 16 x 1 Socket Head Bolt For Wheels 2 10 0022 Screw 1 10 0017 Deflector Screw 1 10 1028 ...

Страница 23: ...N BARB ELBOW 1 8 MPT 10 0406 1 4 ID THREADED HOSE 10 0434 VACUUM GASKET PS10 1030 VACUUM SCREEN 10 0386 VACUUM MOTOR AV06 MA51 SCREW 5 16 X 1 SOC HD FOR WHEEL MOUNT 10 0387 QTY 2 SCREW VAC MOTOR MOUNT QTY 2 10 0014 PLATE VAC MOTOR MOUNT 10 1024 SCREW VAC MOUNT PLATE QTY 2 10 0380 OETIKER HOSE CLAMP 10 0435 NA0840 ...

Страница 24: ...LBOW 1 8 MPT 10 0406 1 4 NYLON BARB X 1 8 MPT NA0839 ACORN STRAINER NA0840 1 4 MALE QUICK CONNECT AH102B 1 4 ID HOSE 10 0434 MA51 1 4 X 1 8 HEX NIPPLE BR130 OETIKER HOSE CLAMP 10 0435 1 8 NPT BULKHEAD FITTING PP11 800091 ...

Страница 25: ...ET 10 0302 A SCREWS 10 0419 QTY 6 SPOTTER HATCH COVER BOTTOM VIEW VACUUM FILTER 10 0431 SPOTTER COVER FLOAT 10 0304 SPOTTER HANDLE ASSEMBLY NM5090 HANDLE HANDLE SLIDE ASSEMBLY 50 0001A RECOVERY TANK NM5090 RT SOLUTION TANK NM5090 ST MA51 ...

Страница 26: ... BACK SWITCH PLATE 10 1025 SWITCH PDRI01 POWER CORD 10 0448 B STRAIN RELIEF 10 0027 NUT 10 0027 A LATCH KEEPER 10 0400C SCREWS 10 0383 QTY 2 SCREW 6 32 X 1 4 10 0383 Old style 4 New Style 2 SOLUTION TANK NM5090 ST RECOVERY TANK NM5090 RT SCREW FOR BASE PLATE 10 0482 FLAT WASHER NM5032 Old style 4 New Style 2 LATCH 10 0400D SCREWS 10 0383 QTY 4 GROUND SCREW NM4061 NUT NM4081 ...

Страница 27: ...pple 1 8 Hex Brass 1 PSA100901 Pressure Relief Valve 175psi 1 BR220 Brass Plug 1 8 1 NM5087 Bulkhead Fitting 1 4 Brass 2 BR020 Barb 3 8 x 1 4 MPT Brass 4 PH07 Hose Clamp 6 10 0843 Hose 3 8 ID Black LP 1 10 0434 Threaded Hose for Spotter 1 NA0839 Barb Nylon Straight 1 8 NPT X 1 4 Barb 4 NA0840 1 8 Strainer for Spotter 1 10 0301 L Bracket For Spotter 1 10 0828 90 Deg Brass Elbow 1 8 MPT 1 10 0022 Sc...

Страница 28: ... 0303 Roller Blade Wheel 2 10 0822 Exhaust Grate 2 10 0419 A Screw For Exhaust Grate 2 10 0014 Motor Screws 2 10 0380 Screw 10 32 x 3 8 2 10 1024 Vac Motor Mounting Plate 1 AV06 Vacuum Motor 1 10 0386 Stamped Motor Screen 1 PS10 1030 Spotter Motor Gasket 1 10 0027 A Strain Relief Nut For Spotter 1 T WBLA Black Wire 10 0027 Pigtail Strain Relief Spotter 1 10 0448 B 20 Ft Spotter Air Mover Cord 1 PD...

Страница 29: ... 10 0419 QTY 6 SPOTTER HATCH COVER BOTTOM VIEW VACUUM FILTER 10 0431 SPOTTER COVER FLOAT 10 0304 SPOTTER HANDLE ASSEMBLY NM5090 HANDLE HANDLE SLIDE ASSEMBLY 50 0001A RECOVERY TANK NM5090 RT SPOTTER BASE W HEAT SP 3 HS GRNGRAN MA51H SOLUTION TANK NM5090 ST ...

Страница 30: ...POWER CORD 10 00448 B SPOTTER BASE MA51H SP 3 HS GRNGRAN VENT GRATE SCREWS 10 0419 A QTY 2 SWITCH PDRI01 MA51H BACK SWITCH PLATE 10 1026 WHEELS QTY 2 10 0303 SCREWS 10 0387 SCREW 6 32 X 1 4 10 0383 MA51H RECOVERY TANK NM5090 RT LATCH KEEPER 10 0400 C SCREWS 10 0383 QTY 2 GROUND SCREW NM4061 NUT NM4081 ...

Страница 31: ...B 3 8 X 1 4 MPT BR020 HOSE 3 8 ID HI TEMP BLACK 90 DEGREE BRASS ELBOW 3 8 BARB X 1 8 MPT 10 0828 VACUUM MOTOR AV06 VACUUM SCREEN 10 0386 VACUUM MOTOR AV06 VACUUM GASKET PS10 1030 PLATE VAC MOTOR MOUNT SCREW VAC MOUNT PLATE QTY 2 10 0380 SCREW VAC MOTOR MOUNT QTY 2 10 0014 ...

Страница 32: ...K VALVE 1 4 MPT NM5069 MA51H Heater Assembly HEATER 600W PSA100910 COMPLETE WITH FITTINGS PRESSURE RELIEF VALVE PSA100901 HEATER ELEMENT ONLY PSA101500B HEATER OUTER SHELL ONLY PSA100900 BULKHEAD FITTING 1 4 NM5087 BARB 3 8 X 1 4 MPT BR020 HOSE HP 1 4 ID HI TEMP BLUE 1 4 JIC FITTINGS PSA001 ELBOW 90 1 4 FPT X 3 8 BARB Heater is secured to Spotter Base with two screws Flat Washers 2 SCREW 10 32 x 1...

Страница 33: ...ING 1 4 NM5087 NIPPLE 1 4 HEX BR072 RECOVERY TANK NM5090 RT ACORN STRAINER 1 8 FPT NA0840 BARB 1 4 X 1 8 MPT NA0839 1 4 ID HOSE 10 0434 SPOTTER BASE MA51H SP 3 HS GRNGRAN SOLUTION TANK NM5090 ST 1 4 MALE QUICK CONNECT AH102B ...

Страница 34: ...1 1 8 Hose End for 3 16 hose 1 7 AH02 1 4 Hose End for 3 16 hose 1 8 100003 Wire Tie Black 7 5 9 AH90 3 8 LP Gray Solution Hose Sold per foot 0 5 10 PMV124V5 Solution Valve with lever mounting bracket 1 11 PMF8002 Tee Jet for hand tool 8002 1 12 PMF011 Retaining Plate for jet on hand tool 1 13 BR304 Compression fitting 1 8 MPT 1 NS PMV124V5B Valve Repair Kit 1 AW55H HOSE TOOL ASSEMBLY 1 11 10 2 3 ...

Страница 35: ...rranty shall not apply to defects resulting from improper operation lack of maintenance unauthorized modification chemical incompatibility misuse abuse or exposure to freezing temperature conditions It does not cover normal wear items such as o rings valve seals pump seals hoses jets cords batteries or other items which require replacement as a result of ordinary usage To obtain warranty service f...

Отзывы: