10
Section
2
Troubleshooting –
Power X Pro Spot Extractor
Problem
Cause
Solution
Machine not
Building circuit breaker tripped.
Reset breaker or move cord to other outlet
turning on -
Faulty power cord
Replace cord
No power
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
Solution
Building circuit breaker tripped.
Reset breaker or move cord to other outlet.
Pump
Faulty power cord
Replace cord
not running
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
Pump faulty
Replace Pump (AP30)
Low Solution
Jet too large for pressure desired
Check jet size & flow rates use smaller jets
Pressure
and/or
Jet worn allowing too much flow
Replace jet
Pulsation
Solution inlet filter plugged
Clean or replace filter
Hose from solution tank restricted Repair or replace hose
Heater Restricted with scale
(MA51H Only)
De-scale or replace the heater
Pressure Relief valve stuck open
(MA51H Only)
Replace the pressure relief valve
Pump intake hose or fittings
leaking
Repair or replace hose. Tighten clamps or replace fittings
Solution tank empty
Add water to tank - Check & repair auto fill assembly
Pump faulty
Repair or replace pump (AP30)
Tool valve faulty
Repair or replace valve
Quick connects or hoses
restricted
Clean out or replace quick connects and/or hoses
Can't connect
Pressure in lines
Turn off pump - Release pressure
solution hose
Quick connects faulty
Replace quick connects (AH101B, AH102B)
to machine
Wrong style/size quick connects
Replace quick connects to match connects on machine
Heater not
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
Heating
(MA51H Only)
Temperature Switch tripped
Reset manual reset temperature switch.
Faulty temperature switches
Replace temperature switches on heater
Faulty Heater
Replace heater
Flow too high for proper heating
Use smaller jet or slow use of water
Water Starting out too cold
Heat water before filling tank – Maximum 120˚F
* To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by
experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
Troubleshooting