31
FLUSH SOLUTION TANK AND PUMP: (continued from previous page)
•
Disconnect the solution hose and tool.
•
Use the vacuum hose to vacuum the remaining acid solution out of the solution tank.
•
Pour two or three gallons of clean water into the solution tank.
•
Connect the pump priming hose to the solution outlet female quick connect.
•
Direct the end of the prime hose into the recovery tank vacuum barb.
•
Turn one or both of the vacuums ON and turn the solution pump ON. Let the pump run until most of
the water has been pumped out of the solution tank.
Do not let the pump run dry. Turn the pump OFF before the water gets to the
bottom of the tank.
•
Turn the vacuums OFF and disconnect the prime hose.
•
Place a bucket under the drain valve and open the drain valve to drain the water out of the recovery tank.
•
Close the drain valve and dispose of the water.
CLEAN PUMP INLET FILTER
A restricted Pump Inlet Filter can prevent the solution pump from providing adequate pressure for cleaning.
A restriction or air leak on the pump inlet hose can also
damage the solution pump check valves and plunger seals.
•
To examine the filter, open the solution tank lid on
the front of the machine. The filter is in the bottom
of the solution tank.
•
Grasp the filter cap and unscrew the filter from the
brass nipple by turning counter-clockwise. Clean
or replace the filter as needed (PP14-806504).
Before proceeding with this procedure,
drain the solution tank & recovery tank. Make sure
both power cords are disconnected.
•
To examine the pump inlet hose, release the latches
on the front/bottom of the machine and tilt the tanks off of the base assembly.
•
Examine the hose for kinks, clogs or holes and repair or replace the hose as needed.
(Replacement Hose: NM5086 – sold per foot)
•
Tilt the tanks back onto the base and secure the latches.
SOLUTION FILTER
PP14-806504
Inside View: MX3-500H Solution Tank
Vacuum acid solution out of
Solution Tank
Drain Recovery Tank
Содержание Nautilus MX3-500H
Страница 1: ...1 REVISED 01 29 2015 LMANN14 MX3 500H Nautilus Operating Manual ...
Страница 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Страница 40: ...40 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Страница 41: ...41 2 4 4 6 7 10 11 3 8 9 3 5 1 8 9 8 9 2 39 12 8 9 ...
Страница 45: ...45 48 49 49 47 47 47A 47A 47 47A 51 51 37 9 54 64 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 47 47A ...
Страница 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK ...
Страница 50: ...50 96 91 97 9 88 111 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 118 ...
Страница 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 97 9 118 ...
Страница 52: ...52 HEATER PARTS 42 42A 98 114 110 71 113 114 ...