background image

AP21 

Water Pump 

1

NM4114 

Coil Hose, 15’ 

1

100010 

Spray Gun Valve 

1

NA0833 Extension 

1

B281 

Veejet 8005 ¼” FPT 

1

NM4102 Bottle 

1

NM4103 Cap 

1

NA0840 Strainer 

1

NA0839 

Barb Nylon 

1

NA0817 

Tubing ¼” ID 

60”

NM4104 

Axle Cap 

2

NM4105 Wheel 

1

NM4110 

Extendable Handle 

1

NM4106 

Base Plate 

1

NS123 

Hose Clamps 

4

NS162 

Elbow Barbs 

2

NS125 

Power Recepticle 

1

NM4123 

Screws Power Recepticle 

2

NM4031 

Nuts Power Recepticle 

2

NM4111 

Switch Rocker 

1

100004 Connectors 

4

PA175 

Wire Black 

6”

NM5020 

Wire Red 

2 feet

PA177 

Wire Green 

6”

PA080 

#10 Ring Connector 

2

XHA07 

3/8” Aluminum Axle Rod 

16.75”

NM4113 

Molded Plastic Body 

1

BR335 

Quick Male 

2

BR337 

Quick Female 

1

B006 

Upholstery TeeJet 6501 

1

NM4116 

Rubber Bushing 3/8” 

3

NM4061 

Base Plate Screws 

10

NM4080 

Handle Screws 

2

BR112 

Coupling ¼” FXF 

1

NM4115 

Pump Base Bolts    

2

NM4081 

Pump Base Nuts 

2

NM5033 

Pump Base Washers 

2

NA0802 

Strainer Body 

1

NA0803 Strainer 

1

NA0826 

Teejet Cap 

1

NS129  

Power Cord - Detachable 

1

NM4117 

Rubber Bushing 3/4” 

2

NM4064 

Washer Spacer 

4

NS174 Fuse 

1

NS177 

Fuse Casing 

1

BR060 

Splicer 1/4” Barbs 

1

Complete List of Parts

• Run fresh water through the sprayer after each day of use to flush chemical from 

the pump and hoses.

• Keep chemical containers and strainer screen clean.
• While sprayer and pump are made with chemical resistant materials, and can 

handle a wide range of chemicals, do not assume chemical compatibility.

• Contact your distributor or the manfacturer if you have questions regarding your 

chemicals compatibility.

• No warranty, expressed or implied, can be considered where component failure is 

caused by chemical effects.

• Label all containers to properly identify chemicals.
• Do not use to spray liquids with temperatures above 160°F. (71°C)
• Do not use to spray flammable or combustable liquids.
• Do not use sprayer where flammable vapors are present. 
• Pump can run dry without damage.
• If stored in possible freezing conditions the sprayer must be liquid free or 

winterized with anti-freezing chemical.

• Do not operate without inlet strainer.

Safety and General Maintenance

5

12

PART # 

DESCRIPTION 

QUANTITY

PART # 

DESCRIPTION 

QUANTITY

Содержание FlexiPro AS76

Страница 1: ...ance unauthorized modification chemical incompatibility misuse abuse or exposure to freezing temperature conditions It does not cover normal wear items such as o rings valve seals pump seals hoses jets cords chemical bottles or other items which require replacement as a result of ordinary usage To obtain warranty service for the Flexi Pro Sprayer contact your distributor or Hydro Force If the spra...

Страница 2: ...Diagram 4 Complete Sprayer Parts List 5 Sprayer Body and Gun Diagram 6 Sprayer Body and Gun Parts List 7 Sprayer Base Diagram 8 Sprayer Base Parts List 9 Wiring Flexi Pro AS75 10 Safety and General Maintenance 11 Operation 13 Troubleshooting 14 Warranty Information 16 Notes 15 ...

Страница 3: ...ectant Teejet Hydro Force part B006 size 6501 Troubleshooting Pump not turning on No power Not spraying properly Solution dripping from jet with valve closed Problem Cause Solution No power from outlet Fuse blown Cord faulty Faulty switches or internal wiring Pump motor faulty Pump seized Reset breaker or move cord to another outlet Check fuse replace as needed Replace cord Check wiring test switc...

Страница 4: ...Move the sprayer to the location where the sprayer is to be used 7 Turn the switch to the ON position and spray chemical as needed When the job is completed turn the switch to the OFF position 8 Remove the chemical feed hose from the chemical container and replace the solid cap for storage 9 Place the chemical feed hose into a container filled with water 10 Turn the switch to the ON position and s...

Страница 5: ... NM4117 Rubber Bushing 3 4 2 NM4064 Washer Spacer 4 NS174 Fuse 1 NS177 Fuse Casing 1 BR060 Splicer 1 4 Barbs 1 Complete List of Parts Run fresh water through the sprayer after each day of use to flush chemical from the pump and hoses Keep chemical containers and strainer screen clean While sprayer and pump are made with chemical resistant materials and can handle a wide range of chemicals do not a...

Страница 6: ... plug This sprayer is for use on a nominal 120 volt circuit and has a grounding plug that resembles the plug illustrated in the sketch below Make sure that the power cord for this sprayer is connected to an outlet with the same configu ration as the plug No plug adapter should be used with this sprayer The power cord supplied with the AS76 FlexiPro sprayer is properly sized to handle the electrica...

Страница 7: ...0817 Tubing 48 C NM4116 Rubber Bushings 3 8 2 D NM4110 Extendable Handle 1 E NM4061 Base Plate Screws 10 F NM4080 Handle Screws 2 G NM4105 Wheel 2 H XHA07 3 8 Aluminum Axle Rod 16 75 I NM4104 Axle Cap 2 J NM5020 Wire Red 2 feet K NM4064 Washer Spacer 4 L NM4113 Molded Plastic 1 M NA0840 Strainer 1 N NA0839 Barb Nylon 1 O NM4117 Rubber Bushing 3 4 2 P BR335 Quick Connect Male 1 Q NA0802 Strainer Bo...

Страница 8: ...NS123 Hose Clamps 3 8 4 L NS162 Elbow Barbs 2 M AP21 Water Pump 1 N PA175 Wire Black 6 O NS126 Power Recepticle 1 NM4123 Screws Power Recepticle 2 NM4031 Nuts Power Recepticle 2 P NM4115 Pump Base Bolts 2 NS174 Fuse 1 amp not shown 1 Q NS177 Fuse Casing 1 R BR060 Splicer 1 4 Barbs 1 9 Sprayer Base Diagram Back of Sprayer 8 A E R D F C B Q A D F P H N N G I A L M L K A J K Connect draw tube NA0817 ...

Отзывы: