7.

 

Thermostat: Locate the Thermostat about four feet above the floor, at least a foot from windows, four feet from 
doors and preferably on an inside wall. Run two conductor wire from furnace to thermostat use a thermostat 
suitable for 12V.D.C. 

 
8.

 

Replace the Junction box cover and secure with screw, 

CAUTION

Do not short any leads to ground. Any 

shorting or arcing may damage furnace components and thermostat.

 

 
9.  Vent Installation: Select the vent kit required for your overall installed cabinet and wall depth. (A minimum of 1 

1/4” overlap is required on all telescoping exhaust tubes.) 

Cabinet Depth 

 

Vent Kit  

20 5/8 to 23 3/4.   

D-24 

23 3/4 to 28 5/8   

D-28 

28 5/8 to 32 

 

D-32 

 

A.  Apply mastic or sealant to back of air tube flange (B) slide through outside wall cut out and into furnace air 

channel. 

B.  Apply mastic or Sealant to back outer edge of vent grill 

(Do not plug holes)

. Slide assembly in over furnace 

exhaust tube, push into wall and secure with two screws. 

10.  Mounting: A.  Secure furnace to compartment floor with two screws through holes in control box flange. 

IMPORTANT

:  To assure sufficient return air to the circulating blower, maintain specified clearances. 

B.  Install self trim door by sliding door flange over casing top flange and pushing in on bottom of door. 

 

OPERATING INSTRUCTIONS 

FA-79 “D” Models have direct spark ignition systems conforming to A.N.S. Z2120 standards, There is no pilot light. 
To place furnace in operation: 
1.  Turn gas valve to 'on' position (NOTE: Some models may be equipped with a gas valve that does not have a gas 

control knob). 

2.  Set thermostat to Lowest temperature setting, then to desired temperature (if thermostat has an "off" switch turn to 

"on"). 

NOTE

:  On initial lighting, the burner may not ignite due to air in the gas lines. Repeat step two as necessary until 

burner ignites. 

 
FA-79 “P” Models have piezo ignition systems with pilot burners. 
To place furnace in operation: 
1.  Turn gas valve to "off" position and thermostat to highest setting. Wait five minutes. 
2.  Turn gas valve knob to 'pilot" position. 
3.  Depress gas valve knob and light pilot by depressing igniter. Several strokes may be required if there is air in the 
 

gas lines. 

4.  Hold the knob in for about 30 seconds or until pilot remains burning when the knob is released. 
5.  Turn the gas valve knob to “ON” position and set thermostat to desired temperature. 
 

NOTE

:  FAN SHOULD BE IN OPERATION WHEN TURNING GAS VALVE TO “ON” POSITION. 

 
For Complete Shut Down - All Models 
1.  Turn gas valve knob to "off" position (on units with knob) 
2.  Set thermostat to lowest setting and/or 'off' 
 

PREVENTIVE MAINTENANCE 

1.  Glean complete furnace and air box passageways periodically to remove dust, lint, etc. 
2.  Check gas system for leaks at least once a year. 
3.  Check and clean blower wheel annually, 

www.ApacheOwners.com

Содержание FA-7920S D

Страница 1: ...RPORATION FURNACE MAINTENANCE SERVICE MANUAL CAUTION READ PAGE 1 PRIOR TO FIRING YOUR FURNACE HYORO FLAME CORPORATION 1874 South Pioneer Road SALT LAKE CITY UTAH 84104 Phone 801 972 4621 RV 1 1 7 www ApacheOwners com ...

Страница 2: ...ly filled with water and it is seldom that all of this water is removed The following often happens when the furnace is in operation The gas in a propane cylinder is liquid as it is drawn off it becomes a vapor as does a small amount of the water Then the gas vapor and water vapor proceed to the small orifice in the pressure regulator at 100 lbs PSI pressure or more Passing through this orifice th...

Страница 3: ...should be closed tightly after pilot is lit and before main burner is turned on PILOT OUTAGE If the pilot flame will not stay lit when you release pilot knob check ignition flame size The flame should envelop the top 3 8 to 1 2 of thermocouple and should be approximately 1 1 2 long If pilot flame does not envelop the top 3 8 to 1 2 of the thermocouple with 1 1 2 total length turn pilot gas adjustm...

Страница 4: ...C through an outside wall The Furnace should be as near to the center of the vehicle as possible 1 Provide a 11 1 4 High x 8 3 8 Wide Cabinet opening and 2 7 16 High x 4 15 16 Wide outside wall opening as shown in Fig 3 2 On side discharge ducted models remove left side knock out plate and install two duct adapters 3 Slide Furnace into cabinet opening On side ducted Models Slide 4 D1A Ducts over t...

Страница 5: ...TIONS FA 79 D Models have direct spark ignition systems conforming to A N S Z2120 standards There is no pilot light To place furnace in operation 1 Turn gas valve to on position NOTE Some models may be equipped with a gas valve that does not have a gas control knob 2 Set thermostat to Lowest temperature setting then to desired temperature if thermostat has an off switch turn to on NOTE On initial ...

Страница 6: ... 6 Do not operate the furnace through a battery charger 7 Do not attempt field repairs on the electrical module on D models 8 Do not install the furnace on top of carpeting or store flammable liquids or vapors in the vicinity 9 Do not install furnace where clearances from combustible materials can not be maintained 10 Do not attempt to ignite a direct ignition furnace with a match torch or flint t...

Страница 7: ...6 www ApacheOwners com ...

Отзывы: