background image

 

FUEL LINE STOPPAGE 

 
When a camper or trailer is not in use and fuel lines are disconnected, always plug or protect them from foreign 
material. Mud Daubers love to plug them. Many times the lines are partially plugged, but not completely blocked off, 
so appliances may run, but at a reduced rate. 
 
SMALL TUBING 
 
Use 3/8” or larger tubing when installing Hydro Flame Furnaces. Smaller tubing can drop gas pressure and heat output. 
 

FURNACE GOING OUT? 

 
Pilot door must be closed tightly during operation. 
 
When a Hydro Flame Furnace is in operation, the firebox is usually under a low pressure condition; therefore, if the 
pilot door is even slightly opened or cracked, air will be pulled into the firebox. This stream of air will force the pilot 
flame away from the thermocouple in toward center, which will cool the thermocouple and drop the furnace controls 
out on safety, shutting off all of the gas supply. Pilot door should be closed tightly after pilot is lit and before main 
burner is turned on, 
 

PILOT OUTAGE 

 
If the pilot flame will not stay lit when you release pilot knob, check ignition flame size. The flame should envelop the 
top 3/8” to 1/2” of thermocouple and should be approximately 1 1/2” long. If pilot flame does not envelop the top 3/8" 
to 1/2”' of the thermocouple with 1 1/2” total length, turn pilot gas adjustment screw located on gas valve out, or 
counter clockwise, until a normal size flame is obtained, (See illustration) 

CAUTION. Never bend or try to force thermocouple into pilot flame. 

 
If you have proper gas pressure and pilot flame is still not at normal size, remove orifice from pilot, clean by blowing 
out frontwards and backwards with high pressure air and replace 
 

HEAT OUTPUT UNSATISFACTORY 

 
First, be sure the gas bottle is not overfilled and that you have alcohol in gas bottle and full gas pressure (12”) to 
furnace. Locate sensing bulb further from heat. 
 
If problem still persists, direct your correspondence to: 
 
HYDRO FLAME CORPORATION 
1874 South Pioneer Road 
SALT LAKE CITY, UTAH 84104 

www.ApacheOwners.com

Содержание FA-7920S D

Страница 1: ...RPORATION FURNACE MAINTENANCE SERVICE MANUAL CAUTION READ PAGE 1 PRIOR TO FIRING YOUR FURNACE HYORO FLAME CORPORATION 1874 South Pioneer Road SALT LAKE CITY UTAH 84104 Phone 801 972 4621 RV 1 1 7 www ApacheOwners com ...

Страница 2: ...ly filled with water and it is seldom that all of this water is removed The following often happens when the furnace is in operation The gas in a propane cylinder is liquid as it is drawn off it becomes a vapor as does a small amount of the water Then the gas vapor and water vapor proceed to the small orifice in the pressure regulator at 100 lbs PSI pressure or more Passing through this orifice th...

Страница 3: ...should be closed tightly after pilot is lit and before main burner is turned on PILOT OUTAGE If the pilot flame will not stay lit when you release pilot knob check ignition flame size The flame should envelop the top 3 8 to 1 2 of thermocouple and should be approximately 1 1 2 long If pilot flame does not envelop the top 3 8 to 1 2 of the thermocouple with 1 1 2 total length turn pilot gas adjustm...

Страница 4: ...C through an outside wall The Furnace should be as near to the center of the vehicle as possible 1 Provide a 11 1 4 High x 8 3 8 Wide Cabinet opening and 2 7 16 High x 4 15 16 Wide outside wall opening as shown in Fig 3 2 On side discharge ducted models remove left side knock out plate and install two duct adapters 3 Slide Furnace into cabinet opening On side ducted Models Slide 4 D1A Ducts over t...

Страница 5: ...TIONS FA 79 D Models have direct spark ignition systems conforming to A N S Z2120 standards There is no pilot light To place furnace in operation 1 Turn gas valve to on position NOTE Some models may be equipped with a gas valve that does not have a gas control knob 2 Set thermostat to Lowest temperature setting then to desired temperature if thermostat has an off switch turn to on NOTE On initial ...

Страница 6: ... 6 Do not operate the furnace through a battery charger 7 Do not attempt field repairs on the electrical module on D models 8 Do not install the furnace on top of carpeting or store flammable liquids or vapors in the vicinity 9 Do not install furnace where clearances from combustible materials can not be maintained 10 Do not attempt to ignite a direct ignition furnace with a match torch or flint t...

Страница 7: ...6 www ApacheOwners com ...

Отзывы: