background image

www.hydraconnect.com

(

 720-583-4364

HydraConnect LLC

Safety Information

Please read and understand all instructions in this manual before operating this 

equipment.

 

¾

Keep these instructions in a safe, accessible place for future reference.

 

¾

Pay attention to all warnings, and follow all instructions.  If the equipment 

is used in a manner not specified by the manufacturer, the protection pro-

vided by the equipment may be impaired.

 

¾

Do not use this equipment near water, and unplug the product before clean-

ing and clean only with a dry cloth.

 

¾

Do not install near any heat sources such as heat registers, stoves, or other 

equipment that produce heat.

 

¾

Explanation of graphical symbols:

Exclamation point symbol: the exclamation point within an  

equilateral triangle symbol is intended to alert the user to the  

presence of important operating and maintenance instructions in 

the literature accompanying the product.

 

¾

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, 

DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE AND 

OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD NOT BE 

PLACED ON THIS EQUIPMENT.

 

¾

Do not block the air ventilation openings. Only mount the equipment per 

HydraConnect’s instructions.

 

¾

Ensure that all IR connections are made 

BEFORE

 power is applied to either 

module.  Failure to observe this requirement may result in damage to the 

modules that will not be covered under warranty.

 

¾

NOTE, This equipment has been tested and found to comply with the lim-

its for a Class B digital device, pursuant to Part 15 of the FCC rules. These 

limits are designed to provide reasonable protection against harmful inter-

ference in a residential installation. This equipment generates, uses and can 

radiate radio accordance with the instructions, may cause harmful interfer-

ence to radio communications. However, there is no guarantee that inter-

ference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to 

try and correct the interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna

• 

Increase the separation between the equipment and the receiver

• 

Connect the equipment into a outlet on a circuit different from that to 

which the receiver is connected

• 

Consult the dealer or an experienced radio/TV technician for help

Page 1

Содержание HEXT-21b

Страница 1: ...www hydraconnect com 720 583 4364 HydraConnect LLC HEXT 21b HDBaseT HDMI Extender ...

Страница 2: ...onnections 3 Transmitter Module Connections 3 Receiver Module Connections 3 Product Installation 4 Product Operation 6 Product Maintenance 6 Cable Pinouts 7 IR Cables 7 Link Cable 7 HDMI Cable 7 Technical Specifications 9 Warranty 10 Limited Warranty 10 Customer Remedies 10 No Other Warranties 10 No Liability For Damages 10 Rev 1 1 ...

Страница 3: ...he air ventilation openings Only mount the equipment per HydraConnect s instructions Ensure that all IR connections are made BEFORE power is applied to either module Failure to observe this requirement may result in damage to the modules that will not be covered under warranty NOTE This equipment has been tested and found to comply with the lim its for a Class B digital device pursuant to Part 15 ...

Страница 4: ...nd Deep Color Fully compliant with HDCP Fully 3D Compatible all 7 formats including the most popular e g Frame Packing Side by Side Top to Bottom Supports all latest Audio formats such as Dolby True HD DTS master etc Supports bi directional IR pass through of all frequency band hardware 20K 80KHz all protocols Supports 10 2Gbps HD source signal 4Kx2K Operates over standard CAT5e 6 UTP STP link cab...

Страница 5: ...o be linked to the Receiver module 4 HDMI IN Connect to a HDMI source with a HDMI male male cable 5 IRDA In Infrared 3 5mm socket for plugging in the IR receiver Receiver Module Connections 1 IRDA Out Infrared 3 5mm socket for plugging in the IR flasher 2 CAT5e 6 IN Plug in a Cat 5e 6 cable that needs to be linked to the Transmitter module 3 HDMI OUT Connect to a HDMI Display with a HDMI male male...

Страница 6: ...her or Receiver to the designated connectors NOTE THAT INSTALLING AN IR FLASHER OR RECEIVER INTOTHEWRONGCONNECTORMAYDAMAGETHEMOD ULEWHICHWILLNOTBEREPAIREDUNDER WARRANTY 4 If an automation system IR passthrough is needed connect a 3 5mm mono connector cable between the output of the automation system and the IR input on the transmitter Connect the IR flasher to the IR output on the receiver NOTE Un...

Страница 7: ...ON A VERTICAL WALL FOR PROPER OPERATION AS SHOWN BELOW 7 Connect a High Speed HDMI Male to Male cable between the receiver module and the display 8 If used connect an IR Flasher or Receiver to the designated connectors NOTE THAT INSTALLING AN IR FLASHER OR RECEIVER INTO THE WRONG CONNECTOR MAY DAMAGE THE MODULE WHICH WILL NOT BE REPAIRED UNDER WARRANTY 9 Plug the output power cable from the suppli...

Страница 8: ...not available from the power supply on the receiver no power is available over the link cable HDMI LED ON Data is being received and is HDCP protected BLINK Data is being received and is not HDCP protected OFF No data is being received Link LED ON Link connection is good and unit is powered up BLINK Link connection is good and unit is powered down FLICKER Connection cannot be established OFF No co...

Страница 9: ...Page 7 www hydraconnect com 720 583 4364 HydraConnect LLC Cable Pinouts IR Cables The IR receiver has the following pinout The IR transmitter has the following pinout ...

Страница 10: ...P cable in solid core types 350MHz CAT 6 cable is preferred for best results HDMI Cable The HDMI cable has the following pinout Pin 1 TMDS Data2 Pin 2 TMDS Data2 Shield Pin 3 TMDS Data2 Pin 4 TMDS Data1 Pin 5 TMDS Data1 Shield Pin 6 TMDS Data1 Pin 7 TMDS Data0 Pin 8 TMDS Data0 Shield Pin 9 TMDS Data0 Pin 10 TMDS Clock Pin 11 TMDS Clock Shield Pin 12 TMDS Clock Pin 13 CEC Pin 14 Reserved Pin 15 SCL...

Страница 11: ... 2 Gbps ӹ ӹ CEC and EDID Pass through ӹ ӹ Bi directional IR pass through Signal distance from extender output up to 40 feet 15 meters Frequency support 20KHz to 80KHz Protocol support any protocol ӹ ӹ Recommended link cable is CAT5e UTP STP CAT 6 FTP cable in solid core ӹ ӹ Power source 24VDC 36A 8 6W 100 240V AC input power supply ӹ ӹ Power consumption 8 watts operating 2 watts standby ӹ ӹ Approv...

Отзывы: