background image

© Hydra-Flex, Inc. 2017

PART NAME

PART NUMBER

1

Electric Solenoid Valve Replacement

24 VAC 1001072

24 VDC 1001073

120 VAC 1001074

2 (Shown On Page 4)

Hydra-Cannon Valve O-Ring Replacement Kit

1001155

3

Single Black Hydra-Cannon Replacement Assembly

1001384

4

1/2” NPT Hydra-Cannon Manifold End Fitting Assembly

1001556

5

Hydra-Cannon Interface Fitting Assembly

1001557

6

M12 Junction Block - 6 Port, With 30’ Homerun Cable

3000412

7

M12 Junction Block - 6 Port, With 100’ Homerun Cable

3000750

8

M12 X Din A X Din I Splitter Cable

3000406

9

M12 X Din A X Din I Splitter Cable Medium

3000407

10

M12 X Din A X Din I Splitter Cable Long

3000408

11

M12 X Din A Cable

3000350

12

Outlet Pressure Gauge 0-400 PSI Bottom Mount

3000491

13

1/4” Hose Barb Foaming Air Check Valve

3000819

14

Pneumatic Replacement Valve With Regulator

24 VAC 1001274

24 VDC 1001275

120 VAC 1001276

15

Pisco Regulator Replacement

3000543

16

Primary Air Regulator (BX Only)

1001161

17

Primary Air Regulator (AX & TX)

1001184

18

Primary air regulator Replacement Bowl - Aluminum

3000952

19

Primary air regulator Replacement Bowl - Plastic

3000870

20

1” Male Quick Connect - Brass

3000205

21

1” Female Quick Connect - Brass

3000206

22

3/4“ Male Quick Connect - Brass

3000196

23

3/4” Female Quick Connect - Brass

3000197

24

1/2” Male Quick Connect - Brass

3000500

25

1/2” Female Quick Connect - Brass

3000502

26

1” Wye Strainer - 20 Mesh

3000490

27

1” NPT T16 Wye Strainer Screen & Gasket Kit

1001938

28

1/2” Ball Valve - Brass

3000565

29

Thermal Relief Valve - 1/2” NPT

3000323

30

40 GPM Bypass Pressure Regulator - Stainless Steel

3000464

31

Manifold Inlet 1/2” ID Hose X 1/2” NPT Ends - 72” Long

3000579

32

20 GPM Quick Connect Regulator Plumbing Assembly

1001775

33

Replacement/Backup 20 GPM Pump

1001362

34

Outlet Manifold

3000662

35

1” Check Valve - Brass

3000250

36

Quick Connect 9’ Cordset For Pump

3000782

37

Quick Connect Pump Plug - Female

3000783

38

Thermal Overload - Sprecher & Schuh

3000862

39

Timer Relay

3000664

40

Current Sensor - AC

3000666

41

Current Sensor - DC

3000866

42

Contactor - Sprecher & Schuh

24 VAC 3000863

24 VDC 3000864

120 VAC 3000865

43

M12 Cordset (Grey)

3000347

44

3/4” x 72” Hose

3000659

Page | 13

Содержание AQUA-LAB AX

Страница 1: ... Hydra Flex Inc 2017 AQUA LAB AX BX TX CHEMICAL DISPENSING SYSTEM User Manual REV A 4000133 revA0717 Hydra Flex Inc 2017 ...

Страница 2: ...on 4 Chemical Line Connections 4 Pneumatic Connections 4 Electrical Connections 5 Operation 6 Pump Priming Instructions 6 Water Flow Rate and Chemical Dilution Set Up 6 Post Installation Vacuum Back Pressure Check 7 Chem Flex Injector Vacuum Check 7 Chem Flex Back Pressure Check 7 Individual Injector Flow Rate Measurement 8 Troubleshooting 8 Appendix 10 Chemical Metering Dilution Charts 10 Termina...

Страница 3: ...ur AQUA LAB to match the requirements needed by your facility SPECIFICATIONS UP to 15 Chemical Ports Up to 15 Pneumatic Ports Hydraulics operating pressure 200 psi Factory set Pneumatics operating pressure 100 psi Factory set Operating Ambient Temperature 40 120 Deg F Operate pumps with 208 230 or 480 Voltages 3 phase Operate Solenoid Valves with 24VAC 24VDC 120VAC 1 1 2 water supply line TX Model...

Страница 4: ...quired TOOLS AND EQUIPMENT NEEDED Unpacking Normal hand tools Assembly Normal hand tools Wiring Normal electrical wiring tools Startup Electrical meter helpful but not required ESTIMATED TIMELINE Unpacking 15 30 minutes Frame Mounting 0 5 2 0 hours Fluid Connections 0 5 2 0 hours Motor Valve Wiring 1 4 0 hours Startup adjustment 1 5 6 0 hours UNPACKING The AQUA LAB is shipped in a wooden crate for...

Страница 5: ...inet 1 wide x 1 high of wall space MOUNTING OF COMPONENTS Aqua Lab Systems TXF Position on the floor in optimal location can be anchored with included anchor feet TXW Mount to concrete or cinder block wall with 4 concrete anchors AX Mount to concrete or cinder block wall with 4 concrete anchors BX Mount sturdy wall with 4 appropriate anchors Pump Assemblies Does not apply to TXF Single Pump Mount ...

Страница 6: ...he line in the storage container Chemical Solution Connections Solution tube recommendation 1 2 OD Poly Tubing Adapt hose to chemical injector using customer preferred connection type 3 8 1 2 OD Tube Push Fittings are provided Feed hose through solution outlet holes Larger diameter holes Metering tips will need to be installed to set dilution ratio see Operation section below PNEUMATIC CONNECTIONS...

Страница 7: ... LABEL MAIN TRUCK CABLE WIRE COLOR MANIFOLD POSITION Ground N A Green Yellow N A DO NOT USE N A Blue N A Hot N A Brown N A Station 1 1 White 1 Station 2 2 Green 2 Station 3 3 Yellow 3 Station 4 4 Grey 4 Station 5 5 Pink 5 Neutral Common 6 Red N A STATION OR USE M12 LABEL ON BOX LABEL MAIN TRUCK CABLE WIRE COLOR MANIFOLD POSITION Ground N A Green Yellow N A Neutral Common N A Blue N A DO NOT USE N ...

Страница 8: ...nd that 200 psi can be reached 5 TX Model Slowly open the priming ball valve located off the end of the distribution block and allow water to flow until steady then close the valve a hose could be connected to the valve to the drain to avoid excessive water on the floor 6 AX and BX Models With the pump off disconnect the high pressure line to the AquaLab at the quick disconnect and point in a safe...

Страница 9: ...X INJECTOR VACUUM CHECK 1 At the Chem Flex Injector remove the chemical feed line from the injector hose barb 2 Attached the tubing of the vacuum gauge to the Chem Flex hose barb 3 With the pump s on manually activate the chemical that is to be tested at the main car wash control cabinet An injector that is working properly will have a reading greater than or equal to 18 in Hg 4 Repeat steps 2 4 f...

Страница 10: ...art or entire pump Excessive Noise from Pump Pump not secured firmly Secure properly Restricted Inlet Clean or correct restriction Cavitation Sounds like marbles in pump Increase inlet size Pump Leaks Worn mechanical seal Replace shaft seal Worn o ring seals Replace Injector is not drawing chemical Passes Vacuum Pressure check test Clogged chemical feed Check chemical hose foot valve meter ing tip...

Страница 11: ...ctor Flow Rate Selection Replace with desired injector size System pressure too low Ensure system pressure is set at 200 psi Downstream pluming restrictive Perform Back pressure test outlined in Section IV of this manual if over 66 psi increase tube size and reduce elbows turns or other restrictive plumbing No flow from injector Solenoid valve malfunction Ensure valve is receiving the correct elec...

Страница 12: ...286 1 1557 ORANGE 1 23 1 44 1 64 1 78 1 137 1 196 1 215 1 293 1 314 1 365 1 437 1 536 1 751 1 874 1 1136 1 1262 TURQUOISE 1 17 1 31 1 45 1 55 1 91 1 126 1 134 1 185 1 197 1 230 1 274 1 336 1 561 1 752 1 885 1 1099 PINK 1 14 1 24 1 35 1 42 1 68 1 93 1 98 1 130 1 143 1 159 1 188 1 224 1 372 1 473 1 570 1 728 LIGHT BLUE 1 11 1 17 1 24 1 31 1 47 1 64 1 66 1 93 1 98 1 114 1 136 1 166 1 318 1 406 1 483 ...

Страница 13: ...ert through cable gland as shown Figure 3 4 Using a small screwdriver press into the spring terminal and pull away from the wire terminal to open the spring clamps Insert the wire that corresponds to the labeled color then release the spring by removing the screw driver Figure 4 5 Repeat for all colors labeled brown and red are not used 6 Blue and Green Yellow are to be wired to the common and gro...

Страница 14: ...dra Flex Inc 2017 Page 12 1 15 12 30 4 14 1 12 3 15 16 6 or 7 18 or 19 25 4 3 22 33 15 1 3 12 30 42 38 25 33 33 44 30 31 26 23 40 or 41 37 39 6 or 7 REPLACEMENT PANEL PUMP MCU PARTS LIST AQUA LAB AX BX TX ...

Страница 15: ...r AX TX 1001184 18 Primary air regulator Replacement Bowl Aluminum 3000952 19 Primary air regulator Replacement Bowl Plastic 3000870 20 1 Male Quick Connect Brass 3000205 21 1 Female Quick Connect Brass 3000206 22 3 4 Male Quick Connect Brass 3000196 23 3 4 Female Quick Connect Brass 3000197 24 1 2 Male Quick Connect Brass 3000500 25 1 2 Female Quick Connect Brass 3000502 26 1 Wye Strainer 20 Mesh...

Страница 16: ... Hydra Flex Inc 2017 Page 14 T 952 808 3640 F 952 808 3650 www hydraflexinc com sales hydraflexinc com 4000133 revA0717 ...

Отзывы: