![Hydra-Flex AQUA-LAB AX Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/hydra-flex/aqua-lab-ax/aqua-lab-ax_user-manual_2191644012.webp)
© Hydra-Flex, Inc. 2017
Page | 10
APPENDIX: CHEM-FLEX INJECTORS - CHEMICAL DILUTION RATIOS
3.00”
1: 251
1: 503
1: 754
1: 1006
1: 1509
1: 2012
1: 2263
1: 2416
1: 2460
1: 2628
1: 4526
1: 5532
1: 8047
1: 10059
1: 12070
1: 15088
2.00”
1: 181
1: 363
1: 544
1: 726
1: 1089
1: 1451
1: 1633
1: 1402
1: 1337
1: 1510
1: 3266
1: 3991
1: 5806
1: 7257
1: 8708
1: 10885
1.00”
1: 104
1: 208
1: 311
1: 415
1: 623
1: 831
1: 934
1: 835
1: 778
1: 898
1: 1869
1: 2284
1: 3322
1: 4153
1: 4983
1: 6229
0.75”
1: 82
1: 165
1: 247
1: 329
1: 494
1: 659
1: 741
1: 642
1: 668
1: 755
1: 1483
1: 1812
1: 2636
1: 3295
1: 3954
1: 4942
0.50”
1: 59
1: 119
1: 178
1: 238
1: 357
1: 475
1: 535
1: 487
1: 496
1: 558
1: 1069
1: 1307
1: 1901
1: 2376
1: 2852
1: 3564
0.25”
1: 34
1: 68
1: 102
1: 136
1: 204
1: 272
1: 306
1: 282
1: 304
1: 344
1: 612
1: 748
1: 1088
1: 1360
1: 1632
1: 2040
#8-32 METERING TIPS
Flow Rate (GPM) at 200 PSI
0.25
0.50
0.75
1.00
1.50
2.00
2.25
3.00
3.25
3.75
4.50
5.50
8.0
10.0
12.0
15.0
Injector Color
White
Yellow
Ta
n
Red
Orange
Gray
Blue
Light Blue
Light Gr
een
Pink
Purple
Dark Gr
een
Black
Black
Black
Black
Nozzle Size
0.029” (0.7 mm)
0.040” (1.0 mm)
0.051” (1.3 mm)
0.057” (1.4 mm)
0.070” (1.8 mm)
0.083” (2.1 mm)
0.086” (2.2 mm)
0.095” (2.4 mm)
0.098” (2.5 mm)
0.106” (2.7 mm)
0.117” (2.9 mm)
0.125” (3.2 mm)
0.161” (4.1 mm)
0.117” (4.5 mm)
0.186” (4.7 mm)
0.207” (5.3 mm)
COPPER
1: 57
1: 104
1: 155
1: 195
1: 281
1: 406
1: 468
1: 598
1: 629
1: 739
1: 881
1: 1074
1: 2019
1: 2318
1: 3324
1: 4259
PUMPKIN
1: 43
1: 82
1: 119
1: 126
1: 238
1: 348
1: 398
1: 519
1: 554
1: 647
1: 774
1: 946
1: 1465
1: 1832
1: 2310
1: 3042
BURGUNDY
1: 34
1: 67
1: 97
1: 111
1: 207
1: 304
1: 347
1: 461
1: 495
1: 575
1: 690
1: 845
1: 1244
1: 1670
1: 1975
1: 2469
LIME
1: 28
1: 57
1: 81
1: 100
1: 183
1: 270
1: 307
1: 414
1: 447
1: 518
1: 622
1: 764
1: 988
1: 1262
1: 1481
1: 1958
TA
N
1: 28
1: 57
1: 81
1: 100
1: 183
1: 270
1: 307
1: 414
1: 447
1: 518
1: 622
1: 764
1: 826
1: 1042
1: 1286
1: 1557
ORANGE
1: 23
1: 44
1: 64
1: 78
1: 137
1: 196
1: 215
1: 293
1: 314
1: 365
1: 437
1: 536
1: 751
1: 874
1: 1136
1: 1262
TURQUOISE
1: 17
1: 31
1: 45
1: 55
1: 91
1: 126
1: 134
1: 185
1: 197
1: 230
1: 274
1: 336
1: 561
1: 752
1: 885
1: 1099
PINK
1: 14
1: 24
1: 35
1: 42
1: 68
1: 93
1: 98
1: 130
1: 143
1: 159
1: 188
1: 224
1: 372
1: 473
1: 570
1: 728
LIGHT BLUE
1: 11
1: 17
1: 24
1: 31
1: 47
1: 64
1: 66
1: 93
1: 98
1: 114
1: 136
1: 166
1: 318
1: 406
1: 483
1: 572
BROWN
1: 10
1: 15
1: 22
1: 28
1: 43
1: 58
1: 59
1: 84
1: 88
1: 103
1: 122
1: 150
1: 270
1: 338
1: 408
1: 507
RED
1: 12
1: 17
1: 23
1: 34
1: 45
1: 46
1: 65
1: 69
1: 80
1: 95
1: 116
1: 202
1: 254
1: 306
1: 375
WHITE
1: 12
1: 16
1: 22
1: 31
1: 42
1: 43
1: 61
1: 64
1: 74
1: 88
1: 108
1: 180
1: 226
1: 272
1: 343
GREEN
1: 11
1: 14
1: 20
1: 28
1: 37
1: 38
1: 53
1: 55
1: 65
1: 76
1: 94
1: 160
1: 201
1: 241
1: 300
BLUE
1: 10
1: 12
1: 17
1: 23
1: 30
1: 31
1: 44
1: 46
1: 53
1: 63
1: 77
1: 122
1: 152
1: 185
1: 224
YELLOW
1: 9
1: 12
1: 16
1: 20
1: 22
1: 30
1: 31
1: 36
1: 42
1: 52
1: 80
1: 100
1: 120
1: 148
BLACK
1: 10
1: 13
1: 16
1: 17
1: 23
1: 24
1: 28
1: 33
1: 40
1: 61
1: 77
1: 92
1: 115
PURPLE
1: 6.6
1: 8.3
1: 9
1: 10
1: 13
1: 13
1: 15
1: 17
1: 21
1: 31
1: 39
1: 46
1: 57
GRA
Y
1: 5.3
1: 6.7
1: 6.9
1: 7.6
1: 9.9
1: 10
1: 11.6
1: 13
1: 16
1: 24
1: 30
1: 35
1: 44
OPEN
1: 4.9
1: 5.3
1: 5.2
1: 6.0
1: 6.1
1: 6.1
1: 7.6
1: 8.3
1: 10
1: 12
1: 15
1: 18
1: 23
3/7” polyflow (LLDPE) tubing is r
equir
ed to ensur
e a seal between t
he tube wal
l and t
he spiral plug.
(Assumes feed pr
essur
e of 200 PSI (14 bar))
NOTE:
Dilut
ion rat
ios given ar
e based on drawing water t
hr
ough t
he metering t
ips and ar
e meant as a start
ing point for system configurat
ion.
Resul
ts ar
e expected to vary when drawing chemicals due to d
iffer
ences in viscosity and temperatur
e. Ther
e may be sl
ight variat
ions of performance
in injectors and metering t
ips t
hat ar
e unavoidable due to manufactur
e tolerances. Using t
he same t
ip color fr
om site to site is a good start
ing point.
However
, wit
h t
he potent
ial for variat
ion fr
om part, to part it is r
easonable to st
ill need to do some ad
justments fr
om t
her
e.