SMU1000
Functions / Menu guide
Data logging
Display status, time, and data size
State =
Status at last storage
Time [s] = Remaining time until next storage (storing
interval fixed at 60 seconds)
Size
= Size
=
Specification of data size in kB
or MB
Data logging status
-
„OK…“: Memory card present
-
„No disc“: No memory card present
-
„Disc FULL“: Memory card full
-
„Error“: Other data writing errors.
The MMC card can be removed and reinserted during operation. If no card is
inserted during data storage, this data is lost. When the card is reinserted, the data
that follows is added on to the existing data. If a memory card was not present
during a measurement, this can be recognized by a time gap in the data.
Devices
Automatic scanning of the input and display of the connected sensors or the current
scan phase for each individual sensor.
The status of device A / B / C depends on the sensors
connected.
Special function:
Pressing the button sequence OK – DEL – OK within 2 seconds requests a restart in
order to change the variant with VLxGW.
Status CS1000 / HLB
-
„No sensor“: Sensor is not attached, broken cable
-
„Sync…“: Synchronizing, recognition of waiting time between transfer of
measured values (HDA.ISO Signal)
-
„Sync…OK“: Start impulse recognized, begin transfer of measured values
(HDA.ISO Signal)
-
„Read…“: Reading measured values (HDA.ISO Signal)
Status CS2000 / MCS1000
-
The status at the CS2000 is always "Read..." since it is read in via the counter
entry.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 37 / 48
BeWa SMU1000 34x 3614430a en-us 2012-03-13.doc
2012-03-13