8.4 Changing the filter element - Toploader
In this chapter, you will find the procedure for changing the fil-
ter element.
1x Allen wrench
= 5 mm
1x Allen wrench
= 6 mm
The following steps relate to a
ing.
1.
Switch the hydraulic system/the unit off and close the
shut-off device at inlet (IN) and outlet (OUT).
2.
Secure the unit from being switched on accidentally dur-
ing maintenance.
3.
Perform a depressurization of the filter housing. In order
to do so, carefully open the bleed screw (Air Bleed) on
the filter bowl cover (
= 6 mm). Do not unscrew the
bleed screw completely.
CAUTION! The operating medium escapes.
4.
Keep a suitable container ready to catch the escaping
operating medium.
The contents are ≈ 3 liters.
Empty the filter housing by means of the drain plug
Drain (
= 6 mm).
NOTICE! Without draining equipment, the escaping
operating medium can flow down over the electric