5 | Mounting/installing
HYDAC FILTER SYSTEMS GMBH
46 / 88
MoWa OLF-5Z OLF-10Z 4520794 en-us print
5.5 Connecting the (IN) suction port
Use a connector that is suitable for the port. The size of the
connection and the type of the threads can be found in the
"Technical data" chapter
Note the following when connecting the filter housing:
1.
Connect the filter housing to the return line from the hy-
draulic system.
NOTICE
Overpressure
The filter unit will be damaged/destroyed
u
Observe the permissible pressure at the suction port (IN).
If you expect coarse contamination (> 100 µm) in the operating
medium, e.g. due to weld splatter, metallic particles from the
assembly or someting similar, install a protective screen up-
stream of the filter unit in order to protect the pump.
When assembling the filter unit below the oil level, install a
shut-off valve in the line near the filter unit.
1
2
3
4
5
6
7
8
A
Содержание OLF-10/Z
Страница 87: ......
Страница 88: ...www hydac com ...