Setting up / fastening MRF
HYDAC FILTER SYSTEMS GMBH
en
Page 20 / 36
BeWa MRFD4 3342322a us 2010-05-20.doc
2010-05-20
Setting up / fastening MRF
Place the MultiRheo Filter on a flat horizontal surface that has a sufficient load-
carrying capacity and resilience.
Make sure to leave sufficient room, at least 1 m, over the filter housing to change
the filter element.
Fasten the filter with 6 suitable floor anchors.
Hydraulic connection of the MRF
Connect the MRF hydraulically using a flexible hose connection or pipeline.
Make sure that no vibrations and/or stress from other machinery and equipment are
carried over to filter housing.