E
7 Output settings
7.1 Switching outputs
The HNS 526 has either 1 or 2 switching outputs. The following settings can be made under
the basic settings:
7.1.1 Switch point setting (SP)
One switch point and one switch-back point can be set for each switching output. The
particular output will switch when the pre-set switch point is reached and then switch back
when the level drops below the switch-back point.
Example for switch point 1 (N/C and N/O function):
Abbreviations:
"SP1", "SP2"
= switch point 1 / switch point 2
"RP1", "RP2"
= switch-back point 1 / switch-back point 2
"HNO",
= N/O when hysteresis function is active
"HNC"
= N/C when hysteresis function is active
Note:
It is only possible to set the switch point (SP) if it is higher than the respective
switch-back point (RP). In the case of low SPs we recommend setting the RP first.
Level
On
Normally open function
Off
On
Normally closed function
Off