P
art
no
.:
669879
/ S
ta
tus:
19
.07.
2012 E
4
1 General
data
1.1 Author, version, date, document name, file name
Author:
R. Heuckelbach (HEUR)
Version: 1.1
Date:
19.07.2012
Document name: Safety Manual
File name:
SM_HLT_1000-Analog-FS_D_E_669879_2012-07-19.pdf
1.2 Version history and revision notes
Version Date
Author Revision
V1.0 2012-05-24
HEUR First
edition
V1.1
2012-07-19 HEUR
Correction of specifications
2 Scope
This safety manual applies to the following Linear Position Transducers in the series
HLT 1000 for functional safety:
HLT 1100-R2-Kxx-Cxx-xxxx-S2PD-000
HLT 1100-00-Kxx-Cxx-xxxx-S2PD-100
HLT 1100-xx-xxx-Cxx-xxxx-S2Pd-xxx
| | | | | | |
| | | | | | +--
Modification
| | | | | | 000 = Standard housing
| | | | | | 100 = OEM Special housing
| | | | | +-------
SIL2/PL=d
| | | | +------------
Measuring range
in mm
| | | +----------------
Interface
| | | C01 = Analogue 4..20mA
| | | C02 = Analogue 20..4mA
| | +--------------------
Connection
| | K01 = Flying lead 1m
| | K02 = Flying lead 2m
| | K05 = Flying lead 5m
| | K10 = Flying lead 10m
| +-----------------------
Type of connection
| R2 = Cylinder integrated
| 00 = Special housing
|
according to modification
+----------------------------
Design
1 = Rod
Содержание HLT 1000 Analog
Страница 2: ...Mat Nr 669876 Stand 19 07 2012 D 2 ...
Страница 10: ...Mat Nr 669879 Stand 19 07 2012 D 10 11 CE Konformitätserklärung ...
Страница 11: ...Mat Nr 669879 Stand 19 07 2012 D 11 12 TÜV Zertifikat ...
Страница 14: ...Part no 669876 Status 19 07 2012 E 2 ...
Страница 22: ...Part no 669879 Status 19 07 2012 E 10 11 CE conformity declaration ...