Shutting off the FAM
FAM 25/45/60/75/95
en(us)
Page 57/160
BEWA FAM25-95 3402054f en(us) 2013-06-13
2013-06-13
Shutting off the FAM
F1
F2
F3
F4
F2 = STOP
F4 = back to "MENU1"
Press the "STOP" key. The power unit starts the after-run phase.
All of the pumps will be switched off, except for the evacuation pump.
Exception: If the heater is switched on, then a cooling phase of 60 seconds
will intervene during which the heater is first shut off. Afterwards, all of the
pumps will be switched off, except for the evacuation pump.
The evacuation pump runs until the "Min" fill level in the vacuum column is
reached.
The run-down phase status is shown in the display
The run-down phase status is shown in the display
The FAM is once again ready for operation when the Start screen appears
on the display.
F1
F2
F3
F4
Close all locking features in the inlet and outlet lines.
Switch off the unit at the main switch.
MENU1
RH
+P
Rel. moisture: Nominal:
30
%
Actual:33%
Temp 22°C Pressure: 970 mbar(abs )
Automatic mode
STOP
Operating mode: Dewa Filtration
START
MENU1
Ready for operation, please press Start