![Hydac FluidAqua Mobil FAM 15 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/hydac/fluidaqua-mobil-fam-15/fluidaqua-mobil-fam-15_operation-instructions-manual_2191248037.webp)
FAM 15/30/50/70
Starting up the FAM
HYDAC Filter Systems GmbH
en
Page
37 /
68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc
2008-10-06
Setting the fluid temperature (only with heater option)
Set the desired fluid temperature on the HDA 5500.
The HDA5500 has two switching points:
•
SP1 – lower switching point: If the fluid temperature reaches the lower switching
point (SP1), the heater will be switched on (typical temperature value : 50°C).
•
SP2 - upper switching point: If the upper switching point (SP2) is reached, the
heater switches off. (typical setting value: 55°C)
If the "Heater" signal lamp in the control cabinet is lit up, the heater is in operation.
The display shows the current fluid temperature at the output of the heater.
Setting the switching points SP1 / SP2
PressPress the "Mode" key to check the switching points. Press the arrow keys to
change the switching point.
The display automatically resets after 5 seconds without any action.