FAM 15/30/50/70
Dimensions
HYDAC Filter Systems GmbH
en
Page
26 /
68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc
2008-10-06
The vacuum in the reactor is regulated with the regulating valve
(8)
.
In the retransfer operation (only in versions with retransfer operation), the fluid is
pumped directly trough the fluid filter
(7)
by means of an external retransfer pump.
When the stop button is pressed, the directional valve
(1)
closes and the drain pump
empties the vacuum chamber empty. When the emergency stop is pressed, the
vacuum pump and the evacuation pump are switched off and the 2/2 directional
valve is closed by a spring.
Possible Applications
Purification operation (dewatering, degassing and filtration).
IN
OUT
The FAM continuously purifies the bypass fluid in the tank.
Retransfer operation (only filtration).
Only for versions with retransfer pump
2
1
The medium is pumped through the filter from tank 1 to tank 2.