CSI-B-1 Model
Code
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 33 / 36
BeWa CSI-B-1 3424452b 2012-04-20 en-us.doc
2012-04-20
Technical Data
General data
Dimensions
142 x 105 x 35
Securing the ERF
Intended for installation on size 35 top hat
rails in accordance with EN 60715
Mounting position
Arbitrary
Ambient temperature range
-40 … 85 °C
IP class
IP40
Weight
0.35 kg
Electrical data
Connection plug
USB (B), 4 x 8-way clamp gibs
Supply voltage
24 V DC, residual ripple <10%, (protected
against polarity reversal)
Power consumption
0.6 Watt max.
Analog output
2-conductor technology
4 - 20 mA active output (max. burden 500
Ω
)
or
2 - 10 V active output (min. load resistor
820
Ω
)
Deviations: +/-1%
Switching output
Relay with
max. switching current 3 A,
max. switching voltage 220 V DC / 250 V AC,
dead open
HSI (
H
YDAC
S
ensor
I
nterface)
1 wire, half duplex