FILTER MAINTENANCE

FIL1610-1839 / 04.19

6.  Maintenance Instructions

6.1 User Instructions for Filters

This symbol is followed by user tips and 

particularly useful information.

• 

 This pressure equipment must only be put into operation in 

conjunction with a machine or system.

• 

The pressure equipment must only be used as stipulated in the 

operating instructions of the machine or system.

• 

This pressure equipment must only be operated using hydraulic or 

lubricating fluid.

• 

It is the responsibility of the operator to comply with the water 

regulations of the country concerned.

This symbol denotes safety precautions, 

the non-observance of which can endanger 

persons and the environment.

CAUTION

• 

  The user must take appropriate action (e.g. venting) to prevent the 

formation of air pockets.

• 

Repairs, maintenance work and commissioning must only be carried 

out by trained personnel. 

• 

Allow the pressure equipment to cool before handling. 

• 

The stipulations of the operating instructions of the machine or the 

system must be followed.

• 

Statutory accident prevention regulations, safety regulations and 

safety data sheets for fluids must be observed.

• 

Filter housing must be grounded.

• 

When working on, or in the vicinity of, hydraulic systems, open flames, 

sparks and smoking are forbidden.

• 

Hydraulic oils and water-polluting fluids must not be allowed to 

enter the soil or watercourses or sewer systems. Please ensure safe 

and environmentally friendly disposal of hydraulic oils. The relevant 

regulations in the country concerned with regard to ground water 

pollution, used oil and waste must be complied with.

• 

Whenever work is carried out on the filter, be prepared for hot oil 

to escape which can cause injury or scalding as a result of its high 

pressure or temperature.

DANGER!

• 

Caution: pressure equipment! Before any work is carried out on the 

pressure equipment, ensure the pressure chamber concerned (filter 

housing) is depressurized.

• 

On no account must any modifications (welding, drilling, opening by 

force...) be carried out on the pressure equipment.

• 

When using electrical clogging indicators, the electrical power supply 

to the system must be switched off before removing the clogging 

indicator connector.

6.2 Maintenance, General

This section describes maintenance work which must be carried out 

periodically. The operational safety and life expectancy of the filter, and 

whether it is ready for use, depend to a large extent on regular and careful 

maintenance.

6.3 Maintenance Measures

• 

Spare parts must fulfil the technical requirements specified by the 

manufacturer.  

This is always ensured when using original HYDAC spare parts.

• 

Keep tools, working area and equipment clean.

• 

After disassembling the filter, clean all parts, check for damage or 

wear and replace parts if necessary.

• 

When changing a filter element, a high level of cleanliness must be 

observed.

6.4  Interval Between Element Changes

In principle we recommend that the filter element is changed every 6 

months or upon indication, whichever occurs first.
We recommend installing the filter with a clogging indicator (visual and/or 

electrical or electronic) to monitor the filter element.
If the clogging indicator responds, it is necessary to change or clean the 

filter element without delay (only W and V elements can be cleaned).
When no clogging indicator has been installed, we recommend changing 

the elements at specific intervals. 

(The frequency of changing the filter 

elements depends on the filter design and the conditions under which the filter 
is operated)

. When filter elements are subject to high dynamic loading it 

may prove necessary to change them more frequently. The same applies 

when the hydraulic system is commissioned, repaired or when the oil is 

changed
The standard clogging indicators only respond when fluid is flowing 

through the filter. With electrical indicators the signal can also be 

converted into a continuous display on the control panel. In this case 

the continuous display must be switched off during a cold start or after 

changing the element.
If the clogging indicator responds during a cold start only, it is possible 

that the element does not yet need to be changed.

Customer Information in respect of Machinery Directive 2006/42/EC

Hydraulic filters are defined as fluid power parts / components and are 

therefore excluded from the scope of the Machinery Directive, sections  

1.4.1 - 1.4.3. They do not bear the CE mark.
Before using these components, ensure compliance with the 

specifications provided by HYDAC Technology Corporation. The 

specifications also contain information on the relevant essential health 

and safety requirements (based on Machinery  

Directive 2006/42/EC).
We hereby declare that the filters are intended to be incorporated into 

machinery within the terms of the Directive 2006/42/EC.
It is prohibited to put the filters into service until the machinery as a whole 

is in conformity with the provisions of the Machinery Directive.

Service address
HYDAC Technology Corporation 

Filter Division

2260 City Line Road 

Bethlehem, PA 18017 

+1.610.266.0100

NOTE

 

The information in this brochure relates to the operating conditions and applications 

described. 

For applications or operating conditions not described, please contact the relevant 

technical department. 

Subject to technical modifications.

Содержание RFLD Series

Страница 1: ...lter into the system check that the operating pressure of the system does not exceed the permitted operating pressure of the filter Refer to the type code label on the filter Filters must be flexibly mounted and not installed rigidly to the floor or used as a pipe support When installing ensure that system forces cannot be transferred to the filter A filter with a stand may only be installed to th...

Страница 2: ...er and remove element holder if present 5 Pull out filter element Examine element surface for dirt residues and larger particles since these can be an indication of damage to components 6 Replace or clean filter element only W HC wire screen and V metal fiber elementscan be cleaned 7 Clean housing and cover 8 Examine filter especially sealing surfaces for mechanical damage 9 Check O rings and repl...

Страница 3: ... 1 V 00305932 00305931 2 2 Profile seal ring PI 2 3 O ring 15 x 1 5 3 Lever for change over valve 01205525 Type CAK CAL 00270383 Type CBX 00245759 Type CCV CCW CCX without lever 4 Seal kit E RFLD W 0 Seal kit E RFLD W 0 V 01270496 01271748 01266694 01271749 01269392 01271750 01269393 01271751 01269394 01271752 01269395 01271062 01269424 01271753 4 1 O ring element 97 8x5 33 68 x 5 97 8 x 5 33 2 pc...

Страница 4: ... Indicator Model Code VM 2 B X Indicator Prefix VM G 1 2 3000 psi Trip Pressure 2 29 psid 2 bar standard 5 72 psid 5 bar optional Type of Indicator A No indicator plugged port B Pop up indicator auto reset BM Pop up indicator manual reset C electric switch SPDT D electric switch LED light SPDT Modification Number Supplementary Details Seals omit Nitrile rubber NBR standard V Fluorocarbon elastomer...

Страница 5: ...facturer This is always ensured when using original HYDAC spare parts Keep tools working area and equipment clean After disassembling the filter clean all parts check for damage or wear and replace parts if necessary When changing a filter element a high level of cleanliness must be observed 6 4 Interval Between Element Changes In principle we recommend that the filter element is changed every 6 m...

Страница 6: ...ORATION Mobile Hydraulic Division 1660 Enterprise Parkway Suite E Wooster OH 44691 1 610 266 0100 HYDAC CYLINDERS LLC 540 Carson Road North Birmingham AL 35217 1 205 520 1220 HYDAC TECHNOLOGY CORPORATION HYDAC CORPORATION Sales Office Operations 510 Stonegate Drive Katy TX 77494 1 281 579 8100 HYDAC TECHNOLOGY CORPORATION HYDAC CORPORATION NW Sales Office Operations 1201 NE 144th St Bldg B Suite 1...

Отзывы: