mounting instructions OLF-5-TAK tank connection kit
HYDAC Filtertechnik GmbH
page 8 of 9
2.3.3 Ventilation
filter
Dismount ventilation filter of hydraulic unit
2.3.4 Seal
Remove seal from tank cover and
clean surface. Put new seal in
place.
2.3.5 Adapter
has to be mounted on oil tank with
fillister head machine screws M5 x
120 and seal
2.3.6
Suction and return connection
Connect „S“ to the suction connec-
tion and „R“ to the return connec-
tion of the bypass filter unit.