Errors and troubleshooting
LVU-CD-10
en(us)
Page 54 / 68
BeWa LVU-CD-10 StdPrm 3993633a en-us 2015-08-26.doc
2015-08-26
Errors and troubleshooting
The following errors could have different causes. The following provides
information on which remedial measures are required.
To reset the error message on the control, switch off the unit at the main
switch for at least three seconds.
Error
Cause(s)
Remedy
LED is dark =
LED is off
No power supply.
Check the feed-line and plug.
The main switch is
switched off but the
power supply is on
Check the main switch.
LED flashing
The main switch is
switched on, during
operation there was
a drop in voltage =>
restart protection.
Switch off the unit at the main
switch for 3 seconds.
LED lights up
LED flashing
LED flashing
The main switch is
on, but the unit is
not running.
Contact HYDAC.
Electric motor /
pump is not running
Interval control is
active. Only with
control type:
"Premium".
Check the interval settings.
Содержание LVU-CD-10
Страница 67: ......