FCU hydraulic connection
Conducting measurements via the integrated pump - SUCTION INLET
NOTICE
Change-over INLET / SUCTION INLET after a high pressure
measurement
The pump will be damaged.
►
Wait at least 5 minutes after a high pressure measurement before
changing over the suction port connection.
The pressure in the installed pulsation damper must first be reduced
via the OUTLET connection.
NOTICE
Severe contamination of the fluid / on the bottom of the tank
The unit will be destroyed
►
Do not prime directly at the bottom of the tank.
►
Do not prime in the sump.
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom of
the tank. All impurities and other particles are deposited on the
bottom of the tank.
A suction strainer for the suction hose of the FCU is available as an
accessory. Details can be found in the "Accessories" chapter on page 98.