Performing maintenance
Clean the suction strainer
NOTICE
Suction strainer missing / operating without a suction strainer
The unit will be destroyed
►
Never operate the unit without a suction strainer.
►
Clean the suction screen regularly.
A suction strainer is fitted into a piece of pipe of the suction line to protect the
pump from coarse contamination.
Check the suction strainer immediately in the event of insufficient suction or
delivery action.
To replace the suction strainer, proceed as follows:
1. Open the screw plug with an
Allen wrench
= 6 mm.
2. Take out the suction strainer
by rotating it with a large, flat
screwdriver in
counterclockwise direction.
CSM-E