![HYDAC FILTER SYSTEMS ContaminationSensor CS 1939 Series Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/hydac-filter-systems/contaminationsensor-cs-1939-series/contaminationsensor-cs-1939-series_operating-and-maintenance-instructions-manual_2191410028.webp)
Assembly, installation and commissioning
ContaminationSensor CS 1939
en
Page 28 /
48
BeWa CS1939 3978342c V100 en-us 2019-10-08.docx
2019-10-08
Flow rate, differential pressure
p
and viscosity
characteristics
Differential pressure
p
and viscosity
characteristics. All the values
indicated in the figures below apply regardless whether the direction of flow is
A->B or B->A.
Note that the permissible measured volumetric flow is 30
… 500 ml/min.
If you are unable to achieve the required flow values, we offer an extensive
line of accessories with various conditioning modules.
For example:
You are using a fluid with a viscosity
of 46 mm²/s at a pressure difference
p
of ≈0.9 bar, so that you achieve a flow rate of approx. 200 ml/min.
The flow rate depends on the viscosity of the medium and the differential
pressure
p
via the sensor.