Assembly, installation and commissioning
ContaminationSensor CS 1939
en
Page 25 /
48
BeWa CS1939 3978342c V100 en-us 2019-10-08.docx
2019-10-08
Mechanical installation/assembly
Mount the ContaminationSensor as shown in the following examples:
1. Wall mounting:
Mount to a wall using two cylindrical
screws having an M8 hexagonal
socket according to ISO 4762 and
having a length of at least 40 mm.
2. Console mounting:
Mount on a console using 4
cylindrical screws having an M6
hexagonal socket according to
ISO 4762.
A
B
100
60
12/16
4xM6
15
2
0
Bottom view
All dimensions in mm.
3. Installing on a mounting plate:
Mount on a mounting plate or
control block using 4 cylindrical
screws having an M6 hexagonal
socket according to ISO 4762.