CMP
Starting up the CMP
Electrical connection of the ContaminationSensor CS1000
The CS1000 is connected to the 24 V power supply at the time the unit is shipped.
Optionally, you can record the measurement data using an HMG3000.
Starting up the CMP
Prerequisite for commissioning is that the CMP is connected hydraulically to the
entire system via IN / OUT and that the electrical power supply has been
established.
Switch on the CMP at the main switch. The counter balance valve is set to 8 bar at
the time the unit is shipped.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 24 / 36
BeWa CMP1321 3765034 en 2012-09-25.doc
2012-09-25