HLT 2100 / HLT 2500 analogue
19
Status: 2015/08/31
HYDAC
ELECTRONIC
GMBH
Part No.: 669943
E
7.3 HLT 2500 - L2 (Flat profile, with magnetic guidance)
Input data
Measuring ranges
50 .. 4000 mm
Housing Aluminium
Output data
Signal output
Current:
4 .. 20 mA or 20 .. 4 mA
Voltage:
0 .. 10 V or 10 .. 0 V
Resolution 16
Bit;
≥
0.005 mm
Ohmic resistance to GND
Current:
200 .. 500
Ω
Voltage: >
2
k
Ω
Accuracy
≤
± 0.5 % FS typ.
Non linearity
± 0.1 mm
to 1,500 mm
± 0.15 mm
> 1,500 mm
Hysteresis
≤
± 0.1 % FS
Repeatability
≤
0.005 mm -
≤
0.05 mm (depends on length)
Temperature coefficient
≤
± 0.004 % FS / °C
Sampling rate
2 ms
Installation position and travel speed
No orientation restrictions
Ambient conditions
Operating temperature range
0 .. +70 °C
Storage temperature range
-30 .. +85 °C, dry
Relative humidity
98 %, non-condensing
- mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance per
DIN EN 60068-2-6 at 50 .. 2000 Hz
≤
10 g
Shock resistance according to
DIN EN 60068-2-27
≤
100 g / 11 ms / half sine
Housing /
Protection class to IEC 60529
1)
Aluminium /
IP 65
Other data
Electrical connection
- Jacketed cable, length 1 m
1)
- Male M16, 6 pole
- Male M16, 8 pole
Supply voltage
24 V DC
±
10 %
Residual ripple of supply voltage
≤
250 mV
PP
Current consumption without output
< 250 mA
Weight
Depends on length
Note:
Reverse polarity protection of the supply voltage and excess voltage protection and short
circuit protection are provided.
FS
(
F
ull
S
cale) = relative to the full measuring range
1)
further variants on request